Incyte Arc Expert - 120
Found in these product categories:
Part/REF # 243950-0211
-
(In Stock)(In Stock)Stock status is updated daily. For real-time status, please contact us.
Specifications
Sensor Family |
Sensor Family
Incyte Arc Expert |
---|---|
Parameter |
Parameter
Viable Cell Density |
Sensor Output |
Sensor Output
Arc: Modbus |
a-length |
a-length
120 mm |
Electrical Connector |
Electrical Connector
VP8 |
Measurement Principle |
Measurement Principle
Permittivity |
Measuring Range |
Measuring Range
0 to 700 pF/cm, equivalent to 5 x 10^5 to 8 x 10^9 cells/mL (mammalian) |
Additional specifications
Accuracy at 25 °C |
Accuracy at 25 °C
Conductivity (at 0 pF): ± 25 µS or ± 1 %Whichever value is greater over the entire measuring range |
---|---|
Precision at 25 °C |
Precision at 25 °C
Permittivity (at 1 MHz): ± 1 pF or ± 1 %Whichever value is greater over the entire measuring range |
Temperature Sensor |
Temperature Sensor
Yes |
Configurable Values |
Configurable Values
VCD, Conductivity, Temperature |
Diameter |
Diameter
12 mm |
Process Connection |
Process Connection
PG13,5 |
Wetted Parts |
Wetted Parts
PlatinumStainless Steel 1.4435 PEEK (Polyetheretherketone) EPDM (Ethylene propylene elastomer) |
O-ring Material |
O-ring Material
EPDM (Ethylene propylene elastomer) |
Surface Quality of Steel |
Surface Quality of Steel
Ra < 0.4 µm (N5) |
Digital Interface |
Digital Interface
RS485 Modbus (max. 31 addresses) |
Baud Rate |
Baud Rate
19200, 38400, 57600,115200 Bd |
Operating Voltage |
Operating Voltage
24 V (± 10 %) |
Serial Number |
Serial Number
Yes |
Certificate |
Certificate
Yes |
Autoclavable |
Autoclavable
Yes, max. Temperature 130 °C (Incyte Arc Revision 00)Yes, max. Temperature 140 °C (Incyte Arc Revision 01 and higher) |
CIP |
CIP
Yes |
Steam Sterilizable |
Steam Sterilizable
Yes, max. Temperature 140 °C |
Operating Temperature Range |
Operating Temperature Range
0 to 60 °C |
Conductivity Range |
Conductivity Range
1 to 80 mS/cm for firmware below CDCUM0030.5 to 80 mS/cm for firmware CDCUM003 and above (with Hamilton calibration) |
Pressure Range bar g |
Pressure Range bar g
0 to 12 bar |
Resolution at 25 °C |
Resolution at 25 °C
0.1 pF/cm |
Max. Accuracy |
Max. Accuracy
Conductivity (at 0 pF): ± 100 µS (for whole operating temperature range) |
Max. Precision |
Max. Precision
Permittivity (over all frequencies): ± 1 pF (for whole operating temperature range) |
Resources
Documents
-
Brochure
-
Catalogs
-
Certificates
- BSE / TSE / Jatropha Statement (PDF)
- Certificate - China RoHS Hazardous Substances in Parts (PDF)
- Certificates for Stainless Steel Material according the Order EN 10204-3.1.B
- Certificates of Quality for Calibration Solutions
- EU Declaration of Conformity - Arc Sensors (PDF)
- EU Declaration of Conformity - Cell Density (PDF)
-
Guides
-
Material Specifications
-
Software Downloads
-
Technical Drawings
-
Technical Manuals
-
Technical Note
-
documents
Related Content
- Cell Density Measurement Guidelines Article
- Predicting Actionable Timeframes in Cell Culture Using Inline Cell Density Measurement Article
- ArcAir Data Modeling Software Article
- The Integral of Viable Cell Density in Biopharma Article
- Arc Sensors - Signal Averaging Article

We're Ready to Help
Hamilton's sales, customer service, and technical support staff are available for questions and additional information about all products and services.
Contact Us