OxyGold Dissolved Oxygen Sensors
OxyGold electrochemical sensors are optimized for trace dissolved oxygen measurement in pharmaceutical, microelectronics, and high-pressure applications.
Trace oxygen measurement for pharma, microelectronics, and high-pressure applications.
Hamilton's OxyGold sensors are electrochemical dissolved oxygen sensors designed for precise measurement of trace oxygen levels (parts-per-billion). Applications include pharmaceuticals, microelectronics, boiler feedwater, and high-pressure environments. The OxyGold line features two models: the OxyGold Arc, which incorporates Arc technology with digital outputs (4-20mA, Modbus) and ArcAir software for configuration; and the OxyGold Traditional, which utilizes a VP connector and nanoamp (nA) current output for compatibility with standard controllers and transmitters.
Benefits of using Hamilton OxyGold DO sensors
View all OxyGold Dissolved Oxygen sensors
Compare Hamilton’s Polarographic DO Sensors
Determine the optimal polarographic dissolved oxygen sensor for your specific application or process by comparing the specifications of Hamilton's OxyFerm FDA, OxyGold, and Oxysens sensors.
Sensor Specifications
| OxyFerm | OxyGold G | OxyGold B | Oxysens | |
|---|---|---|---|---|
| Measuring Range | 10 ppb - 40 ppm (DO) | 1 ppb - 40 ppm (DO) | 8 ppb - 40 ppm (DO) | 40 ppb - 40 ppm (DO) |
| Response Time t98% | < 60 s at 25 °C from air to nitrogen | < 60 s at 25 °C from air to nitrogen | < 60 s at 25 °C from air to nitrogen | < 60 s at 25 °C from air to nitrogen |
| Pressure Range | 0 – 4 bar | 0 – 12 bar | 0 – 12 bar | 0 – 4 bar |
| Hygienic Aspects | Autoclavable, CIP, SIP | Autoclavable, CIP, SIP | CIP | -- |
| Electrolyte | Oxylyte | Oxylyte G | Oxylyte B | Oxylyte |
| Surface Quality | Ra < 0.4 µm (N5) | Ra < 0.4 µm (N5) | Ra < 0.4 µm (N5) | Ra < 0.8 µm (N6) |
| Current in Air | 40 - 80 nA | 180 - 500 nA | 180 to 500 nA | 40 - 80 nA |
| Material | Stainless Steel 1.4435 | Stainless Steel 1.4435 | Stainless Steel 1.4435 | Stainless Steel 1.4435 |
| Polarization Voltage | -670 mV | -670 mV | 0 ± 50 mV | -670 mV |
| O-ring | EPDM | EPDM | EPDM | EPDM |
OxyGold Dissolved Oxygen Sensors Resources
Browse app notes, user guides, specification documents, and more in our Knowledge Center.
Browse app notes, user guides, specification documents, and more in our Knowledge Center.
Browse app notes, user guides, specification documents, and more in our Knowledge Center.
Browse app notes, user guides, specification documents, and more in our Knowledge Center.
Services
Installation, set-up, and calibration support directly on-site. Our field service team ensures your sensors and cables are installed and functioning correctly.
Support for the qualification of Hamilton equipment including complete documentation. Readying your process for GMP manufacturing activities.
Preventative maintenance and regular service contracts. Schedule on-site service dates to ensure your sensors are properly maintained and your process is optimized.
Diagnosing and resolution of process system problems on-site. Finding the root cause and presenting a solution to fit your needs.
User trainings and on-site trainings for technicians. Tailored training ranging from basic operation to advanced calibration and maintenance.
Hamilton's Technical Support team is here to provide product trouble-shooting, repair, application support, virtual start-up support, and more.
For over 75 years, the Hamilton name has been recognized globally for its unwavering commitment to quality. That pledge extends to creating long-term customer partnerships. We're proud to offer in-depth training courses, on-site field support, custom product builds, and so much more.
Connect with a Hamilton expert to discuss solutions for your workflow. We are here to enable your success.