Ensuring Optimal Dissolved Oxygen Measurement Performance

 

Hamilton's Optical Dissolved Oxygen (ODO) Sensor Caps are engineered to provide the best measurement performance in a variety of conditions, including bioprocess, CIP/SIP, and gamma sterilization. We offer a diverse range of ODO caps, including standard options like the H0/H3 and H20, as well as specialized caps such as the chemically resistant H2/H4, the trace measurement optimized L1 and L0, and the single-use integrated Sx. Our strengthened luminophore matrix in caps like the H3 and H4 provides better temperature stability. Beyond our broad product portfolio, Hamilton is dedicated to supporting your needs with reliable supply and a focus on simplified maintenance with single replacement parts. Our experienced Field Service Team is also ready to assist with installation, maintenance, and calibration services

  • I could not be more pleased with my experience with Hamilton!

    My company has been using Hamilton probes for years and have always been happy with their performance! The team is always very helpful in trouble shooting issues and answering any questions that we may have about our probes. Overall, I could not be more pleased with my experience with Hamilton!

    Abigail Mann
    Bioprocessing Fermentation Associate at Heliae Development

Benefits of using Hamilton Dissolved Oxygen Sensor Caps

  • Diverse Cap Options

    Choose the Right Cap for Your Application

  • Enhanced Performance

    Ensure Accurate and Reliable DO Readings

  • Simplified Maintenance

    Simplify Maintenance with Easy Replacement

View all Optical Dissolved Oxygen sensor caps

Part # Sensor Compatibility Product name Response Time Autoclavable Operating Temperature Range Sales Quantity

JavaScript is required to view and filter products in this category.

A solution for every need

  • ODO Cap H3: Suitable  for most biopharmaceutical aqueous applications due to its better temperature stability, reduced calibration frequency, and longer cap life. With low drift and a short response time.​ As a default option for many applications, it is compatible with VisiFerm mA and VisiFerm RS485.
  • ODO Cap H4: Recommended for applications requiring the highest chemical resistance, as measurements are not influenced by lipophilic compounds. The convex design minimizes bubble formation.​ 
    While it shares the benefits of better temperature stability, reduced calibration frequency, low drift and longer cap life with ODO Cap H3, its response time is slightly longer.  This cap is compatible with VisiFerm mA and VisiFerm RS485.
  • ODO Cap H0: Suitable for applications requiring a short response time and compatibility with most fermentation and culture media. It offers a basic design with standard chemical resistance and temperature stability. It is  compatible with the VisiFerm RS485 and the legacy VisiFerm DO sensors
  • ODO Cap H2: Ideal for applications that need high chemical resistance and a hygienic design to simplify cleaning and minimize bubble formation. Suitable for chemically resistant applications where standard temperature stability is sufficient.
  • ODO Cap H2 FFKM: Same convex design and a PTFE membrane as the ODO Cap H2. Additionally, this cap comes with an FFKM seal making it suitable for aggressive applications.
  • ODO Cap L1: Optimized for trace measurements ranging from 0.8 to 2,000 ppb and shows stability against active chlorine and chlorine dioxide. Designed for a fast response time with measurements lower than 15 ppb, it serves as a replacement ODO Cap for VisiTrace mA and VisiTrace RS485
  • ODO Cap L0: Optimized for trace measurements ranging from 0.8 to 2,000 ppb and demonstrates stability against active chlorine and chlorine dioxide. It is designed as a replacement ODO Cap for the legacy VisiTrace DO Ex.
  • ODO Cap H20: The standard option for water applications. As an Optical Dissolved Oxygen sensor cap, it is compatible with the VisiWater DO P Arc.

Optical Dissolved Oxygen Sensor Caps Resources

Browse app notes, user guides, specification documents, and more in our Knowledge Center.

Browse app notes, user guides, specification documents, and more in our Knowledge Center.

Browse app notes, user guides, specification documents, and more in our Knowledge Center.

Browse app notes, user guides, specification documents, and more in our Knowledge Center.

Services

Installation, set-up, and calibration support directly on-site. Our field service team ensures your sensors and cables are installed and functioning correctly.

Support for the qualification of Hamilton equipment including complete documentation. Readying your process for GMP manufacturing activities.

Preventative maintenance and regular service contracts. Schedule on-site service dates to ensure your sensors are properly maintained and your process is optimized.

Diagnosing and resolution of process system problems on-site. Finding the root cause and presenting a solution to fit your needs.

User trainings and on-site trainings for technicians. Tailored training ranging from basic operation to advanced calibration and maintenance.

Hamilton's Technical Support team is here to provide product trouble-shooting, repair, application support, virtual start-up support, and more.

Backed by world-class service and support.

For over 75 years, the Hamilton name has been recognized globally for its unwavering commitment to quality. That pledge extends to creating long-term customer partnerships. We're proud to offer in-depth training courses, on-site field support, custom product builds, and so much more.

Let's Talk

Connect with a Hamilton expert to discuss solutions for your workflow. We are here to enable your success.

Request Type: