EasyFerm Plus ORP Arc 325
Found in these product categories:
Part/REF # 243052
-
(In Stock)(In Stock)Stock status is updated daily. For real-time status, please contact us.
Specifications
Sensor Family |
Sensor Family
EasyFerm Plus |
---|---|
Parameter |
Parameter
ORP |
Sensor Output |
Sensor Output
Arc: Modbus, 4 to 20 mA |
a-length |
a-length
325 mm |
Electrical Connector |
Electrical Connector
VP8 |
Measurement Principle |
Measurement Principle
Combination electrode; ORP potential measured against reference |
Measuring Range |
Measuring Range
-1500 mV to +1500 mV |
Additional specifications
ORP Element |
ORP Element
Pt ring |
---|---|
Membrane Shape |
Membrane Shape
Spherical |
Diaphragm |
Diaphragm
HP-Coatramic |
Number of Diaphragms |
Number of Diaphragms
1 |
Electrolyte |
Electrolyte
Pressurized Phermlyte |
Reference System |
Reference System
Hamilton Everef-F, Silver ion barrier included |
Liquid Earth |
Liquid Earth
Yes |
Temperature Sensor |
Temperature Sensor
NTC 22 kOhm |
Configurable Values |
Configurable Values
ORP: mV; Temperature: °C, K, °F |
Diameter |
Diameter
12 mm |
Process Connection |
Process Connection
PG13,5 |
Wetted Parts |
Wetted Parts
PlatinumGlass Ceramic EPDM (Ethylene propylene elastomer) |
Analog Interface 1 |
Analog Interface 1
4 to 20 mA, programmable |
Analog Interface 2 |
Analog Interface 2
4 to 20 mA for Temp., programmable |
Analog Interface 1 and 2 |
Analog Interface 1 and 2
Galvanically not isolated; pulse width modulation 3.5 kHz |
Digital Interface |
Digital Interface
RS485 Modbus (max. 31 addresses) |
Baud Rate |
Baud Rate
4800, 9600, 19200, 38400, 57600,115200 Bd |
Operating Voltage |
Operating Voltage
7 to 30 VDC max. 150 mW |
Serial Number |
Serial Number
Yes |
Recommended Storage |
Recommended Storage
Hamilton Storage Solution or 3 M KCl |
Certificate |
Certificate
Yes, with measured value in ORP buffer +475 mV |
ATEX Approval |
ATEX Approval
No |
IECEx Approval |
IECEx Approval
No |
Autoclavable |
Autoclavable
Yes, max. Temperature 130 °C |
CIP |
CIP
Yes |
Steam Sterilizable |
Steam Sterilizable
Yes, max. Temperature 140 °C |
Operating Temperature Range |
Operating Temperature Range
Analog interface: 0 to 110 °C; Digital interface: 0 to 140 °C |
Sample min Conductivity |
Sample min Conductivity
100 µS/cm |
Resources
Documents
-
Brochure
-
Catalogs
-
Certificates
- ATEX Certificate TÜV 03 ATEX 7005 X - Analog Sensors and Armatures (PDF)
- BSE / TSE / Jatropha Statement (PDF)
- Certificate - China RoHS Hazardous Substances in Parts (PDF)
- Certificates for Raw Material according the EN 10204-3.1.B
- Declaration of Quality for Calibration Solutions
- EU Declaration of Conformity - Analog Sensors and Armatures (ATEX) (PDF)
- EU Declaration of Conformity - Arc Sensors (PDF)
- IECEx Certificate TUR 14.0001X - Analog Sensors and Armatures (PDF)
-
Material Specifications
-
SDS
-
Software Downloads
-
Technical Drawings
-
Technical Manuals
-
Technical Note

We're Ready to Help