EasyFerm Plus ORP Arc 120
Found in these product categories:
Part/REF # 243050
-
(In Stock)(In Stock)Stock status is updated daily. For real-time status, please contact us.
Specifications
Sensor Family |
Sensor Family
EasyFerm Plus
|
---|---|
Parameter |
Parameter
ORP
|
Sensor Output |
Sensor Output
Arc: Modbus, 4 to 20 mA
|
a-length |
a-length
120 mm
|
Electrical Connector |
Electrical Connector
VP8
|
Measurement Principle |
Measurement Principle
Combination electrode; ORP potential measured against reference
|
Measuring Range |
Measuring Range
-1500 mV to +1500 mV
|
Additional specifications
ORP Element |
ORP Element
Pt ring
|
---|---|
Membrane Shape |
Membrane Shape
Spherical
|
Diaphragm |
Diaphragm
HP-Coatramic
|
Number of Diaphragms |
Number of Diaphragms
1
|
Electrolyte |
Electrolyte
Pressurized Phermlyte
|
Reference System |
Reference System
Hamilton Everef-F, Silver ion barrier included
|
Liquid Earth |
Liquid Earth
Yes
|
Temperature Sensor |
Temperature Sensor
NTC 22 kOhm
|
Configurable Values |
Configurable Values
ORP: mV; Temperature: °C, K, °F
|
Diameter |
Diameter
12 mm
|
Process Connection |
Process Connection
PG13,5
|
Wetted Parts |
Wetted Parts
Platinum
Glass Ceramic EPDM (Ethylene propylene elastomer) |
Analog Interface 1 |
Analog Interface 1
4 to 20 mA, programmable
|
Analog Interface 2 |
Analog Interface 2
4 to 20 mA for Temp., programmable
|
Analog Interface 1 and 2 |
Analog Interface 1 and 2
Galvanically not isolated; pulse width modulation 3.5 kHz
|
Baud Rate |
Baud Rate
4800, 9600, 19200, 38400, 57600,115200 Bd
|
Operating Voltage |
Operating Voltage
7 to 30 VDC max. 150 mW
|
Serial Number |
Serial Number
Yes
|
Recommended Storage |
Recommended Storage
Hamilton Storage Solution or 3 M KCl
|
Certificate |
Certificate
Yes, with measured value in ORP buffer +475 mV
|
ATEX Approval |
ATEX Approval
No
|
IECEx Approval |
IECEx Approval
No
|
Autoclavable |
Autoclavable
Yes, max. Temperature 130 °C
|
CIP |
CIP
Yes
|
Steam Sterilizable |
Steam Sterilizable
Yes, max. Temperature 140 °C
|
Operating Temperature Range |
Operating Temperature Range
Analog interface: 0 to 110 °C; Digital interface: 0 to 140 °C
|
Sample min Conductivity |
Sample min Conductivity
100 µS/cm
|
Resources
Documents
-
Brochure
-
Catalogs
-
Certificates
- ATEX Certificate TÜV 03 ATEX 7005 X - Analog Sensors and Armatures (PDF)
- BSE / TSE / Jatropha Statement (PDF)
- Certificate - China RoHS Hazardous Substances in Parts (PDF)
- Certificates for Raw Material according the EN 10204-3.1.B
- Declaration of Quality for Calibration Solutions
- EU Declaration of Conformity - Analog Sensors and Armatures (ATEX) (PDF)
- EU Declaration of Conformity - Arc Sensors (PDF)
- IECEx Certificate - Analog Sensors and Housings (PDF)
- UKCA Declaration of Conformity - Analog Sensors and Armatures (UKEX) (PDF)
-
Material Specifications
-
SDS
-
Software Downloads
-
Technical Drawings
-
Technical Manuals
-
Technical Note

We're Ready to Help
Hamilton's sales, customer service, and technical support staff are available for questions and additional information about all products and services.
Contact Us