The Polyplast sensor offers reliable ORP measurement in low-conductivity water applications. Its Single Pore design ensures fast, clog-free performance, while the robust plastic shaft provides durability and glass bulb protection.

Receive More Information

  • Polyplast ORP BNC sensor

Commonly Grouped Accessories

Polyplast ORP BNC Details

The Polyplast ORP is a maintenance-free ORP sensor specifically designed for water applications. They excel in challenging low-conductivity samples such as wastewater, fish farming, and groundwater. Their innovative Single-Pore liquid junction ensures optimal measurement results through direct contact between the sample and the Polisolve electrolyte, virtually eliminating clogging. 

The robust plastic shaft and integrated glass bulb protection, enhance durability in demanding environments. This sensor offers a combination of reliable performance and ease of use for various water-based applications.

Common applications Water, Energy, & Environment, Water and Wastewater

Maintenance-free design: elimination of clogging with a single pore junction.

Good performance in low-conductivity samples.

Robust plastic shaft protects the glass bubble.

Direct Sample Contact, No Clogging

The Single Pore liquid junction ensures direct contact between the sample and the Polisolve electrolyte, making clogging nearly impossible for consistent performance.

Easy Maintenance

Features a non-refillable electrolyte design, eliminating the need for routine maintenance and simplifying operation.

  • Hamilton pH sensors are characterized by their high measuring accuracy and long service life.

    Hamilton pH sensors are characterized by their high measuring accuracy and long service life. This contributes significantly to the control of our processes. They also help us to guarantee the required product quality and to further optimize processes.

    Felix Colin
    Bioprocess Engineer, AB Enzymes GmbH
  • The measurement technology from Hamilton is hard to beat in terms of its measurement accuracy and reliability.

    The measurement technology from Hamilton that is used in our brewery is hard to beat in terms of its measurement accuracy and reliability. The planning security and cost stability with the subscription is very attractive and important to us. Hamilton offers great support and is always open to customer requests.

    Holger Bruckes
    Deputy head of Quality Assurance Mönchengladbach Brewery, Branch of OETTINGER Brewery GmbH
  • I could not be more pleased with my experience with Hamilton!

    My company has been using Hamilton probes for years and have always been happy with their performance! The team is always very helpful in trouble shooting issues and answering any questions that we may have about our probes. Overall, I could not be more pleased with my experience with Hamilton!

    Abigail Mann
    Bioprocessing Fermentation Associate at Heliae Development

Polyplast ORP BNC Specifications

Print
Sensor Family PolyPlast
Wetted Parts Platinum
GΙass
SAN (Polystyrene-Acrylonitrile)
a-length 120 mm
Parameter ORP
Measuring Range -2000 mV to +2000 mV
Electrolyte Polisolve
ORP Element Pt wire
Membrane Shape Spherical
Diaphragm Single Pore
Number of Diaphragms 1
Reference System Ag/AgCl
Temperature Sensor No
Minimum Immersion Depth 10 mm
Serial Number Yes
Recommended Storage Hamilton Storage Solution or 3 M KCl
Certificate Yes, with measured value in ORP buffer +475 mV
Diameter 12 mm
Autoclavable No
Steam Sterilizable No
CIP No
Operating Temperature Range 0 to 60 °C
Pressure Range bar g Atmospheric pressure

Polyplast ORP BNC Resources

Browse app notes, user guides, specification documents, and more in our Knowledge Center.

Browse app notes, user guides, specification documents, and more in our Knowledge Center.

Browse app notes, user guides, specification documents, and more in our Knowledge Center.

Browse app notes, user guides, specification documents, and more in our Knowledge Center.

Compare Products
Services

Hamilton offers modular service contracts tailored to your requirements, featuring a basic module complemented by optional add-ons.

Installation, set-up, and calibration support directly on-site. Our field service team ensures your sensors and cables are installed and functioning correctly.

Support for the qualification of Hamilton equipment including complete documentation. Readying your process for GMP manufacturing activities.

Preventative maintenance and regular service contracts. Schedule on-site service dates to ensure your sensors are properly maintained and your process is optimized.

Diagnosing and resolution of process system problems on-site. Finding the root cause and presenting a solution to fit your needs.

User trainings and on-site trainings for technicians. Tailored training ranging from basic operation to advanced calibration and maintenance.

Hamilton's Technical Support team is here to provide product trouble-shooting, repair, application support, virtual start-up support, and more.

Backed by world-class service and support.

For over 75 years, the Hamilton name has been recognized globally for its unwavering commitment to quality. That pledge extends to creating long-term customer partnerships. We're proud to offer in-depth training courses, on-site field support, custom product builds, and so much more.

Let's Talk

Connect with a Hamilton expert to discuss solutions for your workflow. We are here to enable your success.

Request Type: