The Hamilton ODO Cap S0 Kit for the optical measurement of Dissolved Oxygen (DO) is a Single-Use (SU) cap for the VisiFerm SU sensor. It can be integrated into the single-use container within a 1" barbed bag port. The port fitting is available for integrators such as single-use bioreactor manufacturers.
This product is replaced by the ODO Cap S3.
The Hamilton ODO Cap S2 Kit for the optical measurement of Dissolved Oxygen (DO) is a Single-Use (SU) cap for the VisiFerm SU sensor. It can be integrated into the single-use container (e.g., in a well tube) with an inner thread M14x1-LH (Left-Handed thread). The ODO Cap S2 is available for integrators such as single-use bioreactor manufacturers.
The Hamilton ODO Cap S3 Kit for the optical measurement of Dissolved Oxygen (DO) is a Single-Use (SU) cap for the VisiFerm SU sensor. It can be integrated into the single-use container within a 1" barbed bag port. The port fitting is available for integrators such as single-use bioreactor manufacturers.
0 to 62.85 %-vol
0 to 300 %-sat
0 to 62.85 %-vol
0 to 300 %-sat
0 to 62.85 %-vol
0 to 300 %-sat
± 1.0 %-sat (at 100 %-sat) after gamma irradiation and with product calibration
± 2.5 %-sat (at 200 %-sat) after gamma irradiation and with product calibration
± 1.0 %-sat (at 100 %-sat)
± 2.5 %-sat (at 200 %-sat)
All three accuracy values are valid with calibration values provided on sensor label and after product calibration after irradiation and dry storage up to 37 months
± 1.0 %-sat (at 100 %-sat)
± 2.5 %-sat (at 200 %-sat)
All three accuracy values are valid with calibration values provided on sensor label and after product calibration after irradiation and dry storage up to 37 months
24 months after gamma irradiation
37 months after irradiation
37 months after irradiation
EPDM (Ethylene propylene elastomer)
VMQ (Silicone elastomer)
See compliance details in Material Specification document
EPDM (Ethylene propylene elastomer)
VMQ (Silicone elastomer)
See compliance details in Material Specification document
VMQ (Silicone elastomer)
See compliance details in Material Specification document
X-Ray irradiation compatible (up to 50 kGy)
Not validated for autoclavation, Sterilization In Place (SIP), nor Cleaning In Place (CIP)
X-Ray irradiation compatible (up to 50 kGy)
Not validated for autoclavation, Sterilization In Place (SIP), nor Cleaning In Place (CIP)