Compare Products

Flowcell Peek static housing
Flexiflow sensor housing
Flow-Through Cell PEEK TC

Ensure accurate conductivity measurements in your piping systems with this FDA-approved PEEK flow-through cell, specifically designed to facilitate the insertion of the Conducell 4US-T150-50 sensor and eliminate interference from electronic fields in metal pipes.

FlexiFlow SL 10

Achieve reliable pH and oxygen measurements in challenging ion-weak media with the FlexiFlow flow-through cell, featuring a compact and self-draining design for easy integration into systems.

Wetted Parts PEEK (Polyetheretherketone)
(FDA 21 CFR 177.2415; EU 1935/2004, EU 10/2011; USP <88> Class VI - 121 °C)
Wetted Parts Stainless Steel 1.4435
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
For Sensors with Triclamp 1.5"
For Sensors with 120 mm, 12 mm, PG13,5
Dimensions (W x D x H) 100 x 60 x 70 mm
Dimensions (W x D x H)
Process Connection Triclamp 1.5"
Process Connection Swagelok 10 mm
Max. Diameter 70 mm
Max. Diameter 65 mm
Max. Total Length 100 mm
Max. Total Length 175 mm
Min. Total Length 100 mm
Min. Total Length 175 mm
Serial Number No
Serial Number Yes
Certificate No
Certificate Yes, 3.1 certificate with heat number
ATEX Approval No
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb
II 1/2 D Ex ia IIIC T x °C Da/Db
Diameter 35 mm
Diameter 65 mm
Autoclavable Yes
Autoclavable No
CIP Yes
CIP No
Operating Temperature Range -10 to 140 °C
Operating Temperature Range -10 °C to 130 °C
Max. Pressure bar g 3 bar
Max. Pressure bar g 16 bar
Product Family FlowCell
Product Family FlowCell
O-ring Material
O-ring Material EPDM
See compliance details in Material Specification document
Internal Volume
Internal Volume Approx. 5.5 mL
Mounting
Mounting Bottom Screw Mount (4 pcs)
Weight
Weight 1200 g
IECEx Approval
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb
II 1/2 D Ex ia IIIC T x °C Da/Db
EAC Ex Approval
EAC Ex Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb
II 1/2 D Ex ia IIIC T x °C Da/Db
UKEx Approval
UKEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb
II 1/2 D Ex ia IIIC T x °C Da/Db
Steam Sterilizable
Steam Sterilizable Yes
Backed by world-class service and support.

For over 75 years, the Hamilton name has been recognized globally for its unwavering commitment to quality. That pledge extends to creating long-term customer partnerships. We're proud to offer in-depth training courses, on-site field support, custom product builds, and so much more.

Let's Talk

Connect with a Hamilton expert to discuss solutions for your workflow. We are here to enable your success.