Discover how pH, conductivity, ORP, and dissolved oxygen monitoring supports wet gas scrubber control
Wet gas scrubbers are used across a wide range of industries to remove gaseous pollutants and/or particulate matter from process exhaust streams before release to the atmosphere. For gaseous pollutants, wet scrubbers operate by transferring contaminants from the gas phase into a liquid phase, where they can be neutralized, oxidized, reduced, biologically degraded, or subsequently removed through wastewater treatment. However, some scrubber designs, particularly Venturi scrubbers used for particulate control, also rely heavily on physical collection mechanisms such as inertial impaction and droplet-particle collisions rather than gas absorption alone.1,2
The importance of process analytics in wet gas scrubbers depends on the scrubber chemistry, process objectives, and environmental requirements. Common liquid-chemistry measurements include pH and conductivity; ORP and dissolved oxygen are applied where redox or biological objectives justify them. General scrubber-performance monitoring also commonly includes pressure differential, liquid flow, gas flow, and outlet temperature.3 pH is commonly used to control reagent dosing and maintain the required neutralization capacity,3–5, while conductivity can provide information on changes in ionic loading and can support blowdown control when the relationship has been established for the specific scrubber liquor. ORP is relevant when the scrubbing chemistry is deliberately oxidation-reduction controlled,4,6 while dissolved oxygen is mainly relevant in forced oxidation, aerated oxidation, or aerobic biological treatment stages.7–10
As a result, scrubber performance is determined not only by the mechanical design of the tower but also by the ability to monitor and control the chemistry of the recirculating scrubber liquor, as illustrated in Figure 1.2–5. Analytical measurements in scrubber systems often present significant instrumentation challenges, as high solids loading, scaling tendencies, abrasive slurries, gas entrainment, and continuous exposure to aggressive process media can reduce sensor lifetime and increase maintenance requirements.2,3 Consequently, proper sensor selection, representative installation, and maintenance accessibility are critical for achieving reliable long-term process control, maximizing equipment availability, and ensuring environmental compliance.2,11
Appendix Table 1 summarizes the same guidance by scrubber type, while Table 2 summarizes measurement guidance by application type.
Packed Bed Scrubbers
Packed bed scrubbers are among the most widely used wet gas scrubbers for acid gas absorption and chemical neutralization. The scrubber vessel contains structured or random packing that creates a large interfacial area between the gas and liquid phases, allowing efficient mass transfer and pollutant removal. In a typical counter-current arrangement, contaminated gas flows upward through the packing while the scrubbing liquid flows downward.2,12,13 This configuration is commonly used for removing hydrogen chloride (HCl), hydrogen fluoride (HF), sulfur dioxide (SO2), ammonia (NH3), chlorine (Cl2), and other water-soluble gases. Packed-bed designs are generally attractive where efficient gas absorption and moderate pressure drop are required, provided that fouling, liquid distribution, and flooding are controlled.
Because packed-bed scrubber performance depends strongly on maintaining the correct chemical composition of the scrubbing liquor, process analytics play a central role in operation and control. pH is typically the most important measurement because it directly indicates the neutralization capacity of the scrubbing solution and is commonly used to control reagent dosing.3–5 Examples include sodium hydroxide dosing for HCl removal, acid addition for ammonia scrubbing, and alkaline reagent addition for acidic process gases.
Conductivity is often used as a supplementary parameter to monitor changes in ionic loading and to support bleed or blowdown control, provided that the signal is interpreted for the specific liquor composition. In conventional acid-base scrubbing applications, conductivity does not identify individual chemical species, but it provides a practical indication of the overall ionic strength of the circulating liquor. This makes it useful for monitoring salt buildup, supporting bleed control, and identifying changes in scrubber liquor condition.
Where pollutant removal relies on oxidation-reduction chemistry, ORP can provide valuable supplementary information regarding oxidizing or reducing conditions in the scrubbing liquor.4,6 For chlorine safety scrubbers, the World Chlorine Council specifically states that pH is not an indicator of reaction progress, whereas ORP is a useful indicator of reaction progress and endpoint.4,14 The WCC also recommends backup of the ORP endpoint indication by a second online unit or periodic analysis of the liquor, and periodic titration to verify sufficient scrubbing strength and distinguish caustic from carbonate alkalinity. Dissolved oxygen is generally of limited importance in conventional packed-bed scrubbers unless biological treatment or aerated oxidation processes are integrated into the system.
Tray or Plate Scrubbers
Tray scrubbers, also known as plate scrubbers, achieve gas-liquid contact by forcing the gas stream through perforated trays that hold a shallow liquid layer.11,12 As the gas passes through the liquid, intense mixing and froth formation create a large interfacial area for mass transfer, enabling efficient absorption of soluble gases and removal of selected particulate matter.11,12 Multiple tray stages may be installed within a single tower to increase gas-liquid contact and improve overall scrubbing efficiency.
Tray scrubbers are commonly used in sulfuric acid plants, metallurgical operations, refinery processes, and other industrial applications where robust construction and reliable gas absorption are required.2,11,12,15 Compared with packed-bed scrubbers, tray designs are generally more tolerant of particulate loading and fouling, although they may operate with a higher pressure drop.2,13 They are not a subtype of packed-bed scrubbers, but rather a separate gas-liquid contactor design with different mechanical behavior and failure modes.
From a process analytics perspective, tray scrubbers often require similar liquid-phase measurements to packed-bed systems when the underlying chemistry is acid-base neutralization or gas absorption. pH is typically used for reagent control,3 while conductivity supports dissolved salt and blowdown monitoring.5
ORP is only relevant when the process involves redox-active chemistry,4 and dissolved oxygen is generally not required unless an aerated oxidation or biological stage is involved. However, tray-specific issues such as tray fouling, liquid maldistribution, entrainment, pressure-drop changes, and possible tray damage must also be considered. Therefore, pH and conductivity are typically measured in the common sump or recirculation loop, while mechanical condition is better assessed through pressure drop, liquid distribution checks,
and inspection.
Wet Flue Gas Desulfurization Absorbers
Wet flue gas desulfurization absorbers represent one of the most analytically demanding scrubber applications.2,16 These systems are used to remove sulfur dioxide from combustion exhaust gases generated by power plants, waste incinerators, metal smelters, and other industrial combustion processes.2,16 Depending on the design, reagents such as limestone, lime, magnesium oxide, sodium hydroxide, or ammonia may be used. Sulfur dioxide absorbed into the slurry reacts to form sulfite species, which may subsequently be oxidized to sulfate, with gypsum formation in calcium-based systems.2,6,16 The resulting chemistry creates a complex balance between pollutant removal efficiency, reagent utilization, solids formation, oxidation performance, and scaling tendencies.
In these systems, pH is generally the most critical liquid-chemistry measurement because sulfur dioxide absorption efficiency and limestone utilization are strongly related to slurry pH.2,16 Operating at an excessively low pH can reduce SO2 removal efficiency and promote unfavorable scaling or corrosion conditions, while an excessively high pH may increase reagent consumption, solids formation, and scaling tendencies within the absorber system.2,16 For this reason, pH is commonly used to control lime, limestone, or magnesium oxide addition to the absorber system. Conductivity can track aggregate ionic loading and support site-specific blowdown control, but it cannot distinguish chloride, sulfate, residual reagent, or other dissolved ions without calibration and supporting chemical analysis.
Forced-oxidation FGD systems provide one of the clearest examples where oxygen availability may add process value.2,6,16 Forced oxidation requires adequate oxidation-air supply and gas-liquid oxygen transfer to convert sulfite to sulfate and support gypsum formation. Online dissolved oxygen can be informative in some installations, but slurry fouling, spatial gradients, and weak sensitivity during stable operation may limit its value as a stand-alone control variable. ORP may provide supplementary information on the overall oxidation state of the slurry, but it is less specific than dissolved oxygen measurement and should not be treated as the primary oxidation control parameter.6 In this application, pH remains essential for reagent control, conductivity supports dissolved solids and purge management, dissolved oxygen is most relevant in forced oxidation, and ORP is best used as a secondary trend or diagnostic parameter.2,6,16
Spray Towers
Spray towers remove pollutants by injecting scrubbing liquid directly into the gas stream through spray nozzles.2,13 Compared with packed-bed scrubbers, they have a simpler mechanical design, lower pressure drop, and greater tolerance of particulate loading.2,15 However, their gas-liquid contact efficiency is typically lower, which often requires larger tower dimensions or higher liquid circulation rates to achieve comparable pollutant-removal performance. Spray towers are frequently used for preliminary pollutant removal, acid-gas scrubbing, particulate contact, and, in some cases, cooling or quench-type duties.2,15
The role of process analytics in spray towers is primarily linked to maintaining the chemistry of the recirculating liquid rather than monitoring the tower internals directly. As in packed-bed systems, pH is generally the primary control parameter when chemical absorption or neutralization is involved. Conductivity is commonly used to monitor dissolved solids accumulation and determine blowdown requirements. Where oxidizing or reducing reagents are employed, ORP may provide additional information regarding reaction conditions and chemical residuals. Because spray towers generally rely on relatively simple chemical absorption mechanisms,4 dissolved oxygen measurements are less frequently required unless the system includes aerated oxidation or biological treatment.7–10
Reliable measurement location is particularly important in spray tower systems. Sensors are usually better installed in the sump, recirculation loop, or blowdown stream rather than directly in spray headers or poorly mixed reagent injection zones. This improves measurement representativeness and reduces instability caused by droplets, entrained gas, or local concentration gradients.
Quench Towers
Quench towers are used primarily to cool hot process gases and condition gas streams before downstream scrubbing, filtration, or treatment.2,15 They are common in waste incineration, metallurgical off-gas treatment, sulfuric acid plants, and other applications where hot, corrosive, or dust-laden gases must be rapidly cooled.2,15 Unlike packed-bed or tray scrubbers, the primary function of a quench tower is not always high-efficiency gas absorption. Instead, the main objectives are temperature reduction, gas humidification, condensation control, protection of downstream equipment, and management of dissolved salts or acidic condensate.
From an analytical perspective, pH is important when acidic components are absorbed or condensed into the quench water. This helps operators monitor acidic condensate formation and control chemical addition where neutralization is required. Conductivity is commonly used to monitor dissolved salt buildup and support blowdown control. ORP and dissolved oxygen are generally of limited relevance in typical quench applications unless the quench system is integrated with a redox-active aerated treatment stage.
Quench systems can create difficult measurement conditions because of high temperature, thermal shock, suspended solids, scaling, and corrosive condensate. For this reason, sensors should normally be installed in a cooled, representative liquid stream, such as the quench sump, recirculation line after adequate mixing, or blowdown line. Direct measurement in the hot gas inlet zone should generally be avoided because the environment is usually too unstable and aggressive
for reliable long-term sensor operation.
Venturi Scrubbers
Venturi scrubbers accelerate the gas stream through a constricted throat section where scrubbing liquid is injected; the resulting high relative velocity atomizes the liquid and promotes inertial and diffusional particle capture.17 Venturi scrubbers are used primarily for particulate control and can also remove highly soluble gases when the liquid chemistry and contact conditions are suitable. Some systems combine the Venturi stage with downstream separation, additional scrubbing, and mist elimination.
From an analytical perspective, the major challenge in Venturi scrubbers is often the operating environment rather than the process chemistry itself. High solids loading, abrasive particulates, turbulent flow, gas entrainment, and unstable hydraulic conditions can create demanding measurement conditions. If chemical absorption or neutralization is involved, pH is typically used for reagent control. Conductivity may be used to monitor circulating liquor concentration, dissolved solids accumulation, and blowdown requirements. ORP is only useful when redox-active chemistry is involved, while dissolved oxygen is generally not a routine measurement for Venturi scrubbers.
In Venturi systems used mainly for particulate or mist removal, pressure differential and liquid flow are more directly tied to scrubber performance than liquid-chemistry variables.3,17 Where liquid chemistry is controlled, sensors should not be installed directly in the Venturi throat because of extreme turbulence, erosion, gas entrainment, and unstable flow; representative recirculation tanks, separator outlets, bypass loops, or blowdown lines are preferable measurement locations as an engineering installation practice consistent with the severe throat conditions described in.17
For particulate service, pressure drop reflects the aerodynamic energy available for droplet atomization and particle capture; it is not a direct concentration measurement.2,3,17
Biological Scrubbers
Biological scrubbers combine gas absorption with biological degradation of the absorbed contaminants. In a conventional bioscrubber, pollutants are first transferred from the gas stream into an aqueous scrubbing liquid and are then biologically degraded in a separate bioreactor or biological regeneration stage. The regenerated scrubbing liquid is subsequently recirculated to the absorber.7,9,10
Typical applications include odor control, hydrogen sulfide and ammonia removal, treatment of off-gases from wastewater-treatment or water-purification facilities, and removal of selected water-soluble and biodegradable volatile organic compounds, including alcohols, aldehydes, ketones, organic acids, and esters.7,9,10 Unlike conventional chemical scrubbers, biological scrubbers depend on maintaining suitable environmental conditions for microbial activity, including appropriate pH, temperature, nutrient availability, oxygen supply, and control of accumulated salts and potentially non-biodegradable compounds.7,9,10
In aerobic biological scrubbers, dissolved oxygen is substantially more important than in conventional acid- or caustic-scrubbing systems because oxygen is required for aerobic microbial metabolism. Adequate oxygen transfer is therefore necessary to sustain biological degradation and maintain stable pollutant-removal performance.7–10 However, no universal dissolved-oxygen setpoint is applicable to all biological scrubbers because oxygen requirements depend on the pollutant, microbial population, pollutant loading, reactor configuration, and desired reaction products. In biological hydrogen-sulfide treatment, for example, oxygen availability may influence whether sulfide is converted predominantly to elemental sulfur or is further oxidized to sulfate.8,10
pH is also an important process parameter because it affects gas absorption, microbial activity, pollutant speciation, toxicity, and the products formed during biological conversion.7–10 Rather than assuming that all biological scrubbers operate within one narrow pH range, the required operating range should be defined for the selected microorganisms, pollutant, and treatment objective. For example, slightly alkaline conditions may favor hydrogen-sulfide absorption and the performance of certain sulfur-oxidizing communities, whereas other biological systems may operate effectively under neutral or acidic conditions.7–10
ORP may provide useful supplementary information in biological scrubbers employing redox-controlled chemistry, particularly in sulfide-oxidation systems operated under oxygen-limited conditions. In such applications, ORP can help indicate changes in the overall oxidation state and may support control of sulfur-product selectivity. However, ORP is process- and matrix-dependent and should be correlated with pH, dissolved oxygen, sulfide, sulfate, nitrate, or other relevant analytical measurements rather than being treated as a direct pollutant-concentration measurement.8,10
Conductivity can be used as a secondary indicator of accumulated dissolved ionic species and can support bleed or drainage control. Biological degradation of sulfur- and nitrogen-containing compounds can generate sulfate, nitrate, and other dissolved salts; excessive salt accumulation may inhibit biological activity and therefore requires controlled removal of part of the circulating liquid.7,9,10
Biomass, biosludge, and—where attached-growth configurations are used—biofilm can accumulate on wetted surfaces and contribute to fouling. Sensors should therefore be installed at representative, well-mixed locations with adequate access for inspection, cleaning, calibration, and replacement. The instrumentation layout should also distinguish between a conventional suspended-growth bioscrubber and a biotrickling filter, because biomass location, fouling behavior, and suitable measurement points differ between these configurations.7,9,10
Gas-Phase Monitoring
Although this article focuses on liquid-phase analytical measurements, gas-phase analyzers are frequently used to verify overall scrubber performance and emissions control.3 Depending on the application, gases such as HCl, SO2, H2S, NH3, oxygen, and moisture may be monitored at the scrubber inlet, outlet, or stack. These measurements provide direct confirmation of pollutant removal efficiency and help identify breakthrough conditions that may not be apparent from liquid-phase measurements alone.
In suitable applications, modern gas analyzers such as tunable diode laser systems can provide in-situ measurements without conventional sample extraction.18 Other extractive or in-situ gas measurement technologies may also be used depending on the target gas, process conditions, regulatory requirements, and installation constraints. In many facilities, liquid-phase measurements provide the primary process control signals, while gas-phase measurements provide direct confirmation that the scrubber is achieving its environmental objectives.
Conclusion
The correct analytical measurement in a wet gas scrubber is determined by the underlying process chemistry and the control objective, not simply by the scrubber design. Although scrubber geometry affects installation conditions, fouling risk, and maintenance access, the selection of pH, conductivity, ORP, dissolved oxygen, or gas-phase monitoring must be based on what must be controlled: neutralization capacity, salt accumulation, oxidation state, oxygen availability, or verified outlet emissions. Table 1 summarizes this guidance by scrubber type, while Table 2 provides a complementary view by application type, helping separate equipment-related constraints from the chemical and control requirements that ultimately define the measurement strategy.
Table 1: Wet Scrubber Process Chemistry and Measurement Guidance by Scrubber Type
| Scrubber Design | Target Pollutant / Duty | Typical Process and Scrubbing Chemistry | Monitoring and Control Objectives | Recommended Measurements | Typical Measurement Locations | Main Measurement Challenges |
|---|---|---|---|---|---|---|
| Packed-bed acid gas scrubber | HCl, HF, SO₂, acid mist, partially soluble acidic gases | Alkali dosing; recirculation; sump control; blowdown | Control neutralization; maintain reagent reserve; manage salt/TDS buildup; control bleed |
|
Recirculation sump; representative recirculation line; blowdown line for conductivity | Packing fouling; scaling; corrosive liquor; poor liquid distribution |
| Spray tower scrubber | HCl, HF, SO₂, NH₃, chlorine, soluble gases; preliminary particulate removal; gas cooling and conditioning | Direct-contact gas absorption using sprayed liquid droplets; acid-base neutralization; reagent recirculation; blowdown control | Maintain reagent availability; control neutralization chemistry; manage dissolved solids and salt accumulation; optimize liquid recirculation and bleed rate |
|
Recirculation sump; recirculation loop after complete mixing; blowdown stream; occasionally reagent make-up tank | Poor mixing near reagent injection points; entrained gas bubbles; suspended solids; scaling; variable liquid inventory and circulation rates |
| Tray / plate scrubber | Acid gas or alkaline gas absorption with staged liquid-gas contact | Tray liquid; sump; recirculation; blowdown | Maintain stage chemistry and reagent reserve; manage salt buildup; diagnose fouling |
|
Common sump; recirculation loop; tray liquid sample point if available; blowdown line | Tray plugging; plate fouling/collapse; poor liquid distribution; entrainment |
| Venturi scrubber | Fine particulates, fumes, acid mist, soluble gases with PM capture | Recirculation tank; separator; bleed/blowdown | Maintain scrubbing-liquid condition; support chemical control where used; control bleed/blowdown |
|
Recirculation tank; separator outlet; calm bypass loop; blowdown line. Avoid direct measurement in venturi throat | High solids; erosion; gas entrainment; unstable readings; abrasive particles |
| Quench tower | Hot process gas cooling; acid gas pre-conditioning; incinerator off-gas; metallurgical off-gas | Quench water make-up; recirculation; cooling; blowdown | Control acidic condensate; manage dissolved salts and water balance; limit scaling |
|
Quench sump; recirculation line after cooling/mixing; blowdown line | High temperature; thermal shock; scaling; solids; corrosive condensate |
Table 2: Wet Scrubber Process Chemistry and Measurement Guidance by Application
| Scrubber Application | Target Pollutant / Duty | Typical Process and Scrubbing Chemistry | Monitoring and Control Objectives | Recommended Measurements | Typical Measurement Locations | Main Measurement Challenges |
|---|---|---|---|---|---|---|
| SO₂ scrubber / wet FGD | Sulfur dioxide (SO₂); flue-gas desulfurization | Lime or limestone slurry absorption; sulfite formation; forced oxidation to sulfate/gypsum where applicable; absorber recirculation and purge | Control sorbent dosing and SO₂ removal; support sulfite oxidation and gypsum quality; manage chloride and dissolved-solids buildup |
|
Absorber reaction tank; slurry recirculation line; oxidation tank for DO; purge/blowdown line for conductivity | Gypsum slurry abrasion; scaling and coating; solids loading; plugging; air bubbles; slow response caused by deposits |
| HCl scrubber | Hydrogen chloride (HCl); hydrochloric acid mist | Typically packed-bed or spray tower; water pre-absorption and/or NaOH or KOH neutralization; recirculation with blowdown | Maintain alkali reserve; prevent HCl breakthrough; control chloride/salt accumulation; verify discharge pH |
|
Recirculation sump; representative recirculation line after mixing; final discharge; blowdown line for conductivity | Low-pH attack during upset; high chloride concentration; high ionic strength; coating or scaling; local dosing gradients |
| Chlorine scrubber | Chlorine (Cl₂); mixed chlorine/HCl vent gases; residual oxidants | Typically packed bed with NaOH or KOH; reducing agent such as sodium bisulfite or thiosulfate may be added for oxidant destruction | Maintain caustic reserve; prevent chlorine breakthrough; control reductant dosing; identify spent liquor and salt accumulation |
|
Recirculation sump; reaction tank; recirculation line after caustic/reductant mixing; final discharge; blowdown | High-pH glass error and glass attack; oxidant exposure; ORP dependence on pH and matrix; non-specific conductivity; dosing gradients |
| HF scrubber | Hydrogen fluoride (HF); fluoride-containing acid mist | Typically packed-bed scrubber; KOH or NaOH absorption; lime or Ca-based polishing may be used where fluoride precipitation is desired | Maintain alkalinity; minimize HF breakthrough; manage fluoride salt buildup; support blowdown or precipitation control |
|
Recirculation sump; well-mixed recirculation line; downstream neutralization or precipitation stage; blowdown | HF attacks standard silicate glass; CaF₂ scaling where calcium is present; abrasive or coating solids; high ionic strength |
| NH₃ and amine scrubber | Ammonia (NH₃); amines and alkaline vapors | Acid scrubber, commonly using sulfuric acid; packed-bed or spray-tower contact; ammonium salt accumulates in recirculation liquor | Control acid dosing; minimize NH₃ breakthrough; monitor ammonium salt loading; verify discharge pH and bleed requirement |
|
Acid scrubber sump; recirculation loop after acid mixing; discharge or blowdown line | High ammonium-salt concentration; crystallization or scaling; coating; steep pH response near dosing point; odor breakthrough |
| H₂S and mercaptan scrubber | Hydrogen sulfide (H₂S); mercaptans; reduced-sulfur odor compounds | NaOH absorption with oxidant such as NaOCl or H₂O₂; alternatively biological oxidation in a bioscrubber; aeration may be included | Maintain absorption pH; control oxidant addition; support sulfide oxidation; prevent odor breakthrough; manage sulfate/salt buildup |
|
Reaction tank or sump; recirculation line after oxidant mixing; aerated bioreactor for DO; bleed line | Sulfide poisoning/coating; oxidant attack; pH-dependent ORP; biological fouling; gas bubbles; variable sulfur speciation |
| VOC and odor bioscrubber | Water-soluble or biodegradable VOCs; H₂S; NH₃; mixed odor compounds | Gas absorption into recycle liquid followed by biological degradation; nutrient dosing, aeration, pH control, and bleed | Maintain biological activity; control aeration and nutrient balance; avoid inhibitory pH; track salinity and process stability |
|
Bioreactor or recycle tank; aerated zone for DO; representative recirculation line; bleed line | Biofilm and biomass coating; slow biological response; bubbles; sensor drift; variable VOC biodegradability; unstable ORP |
| Acid mist and fine-particulate wet scrubber | Acid mist, fumes, and fine particulate matter, with or without soluble acid gases | Venturi scrubber or high-energy spray device followed by separator; recirculated water or chemically adjusted liquor; blowdown | Maintain scrubbing-liquid condition; control chemical addition where used; manage solids and dissolved-salt accumulation; support bleed control |
|
Recirculation tank; separator outlet; calm bypass or sidestream loop; blowdown line; avoid direct installation in venturi throat | Abrasive solids; erosion; entrained gas; turbulence; unstable readings; plugging and fouling |
| Bromine scrubber | Bromine (Br₂); HBr and bromine-containing vent gas | Packed-bed caustic scrubber; NaOH or KOH absorption; bisulfite or thiosulfate reduction may be used depending on process chemistry | Maintain alkalinity and reductant reserve; prevent bromine breakthrough; detect liquor exhaustion; manage bromide/bromate salt accumulation |
|
Sump; reaction/hold tank; recirculation line after mixing; discharge verification point | Strong oxidant exposure; pH-dependent ORP; high salt concentration; electrode coating; material compatibility |
Chemical Industry Application Notes
Save This Article for Later
References
- Wang, L. K.; Taricska, J. R.; Hung, Y.-T.; Eldridge, J. E.; Li, K. H. Wet and Dry Scrubbing. In Air Pollution Control Engineering; Wang, L. K., Pereira, N. C., Hung, Y.-T., Eds.; Humana Press: Totowa, NJ, 2004; pp 197–305. https://doi.org/10.1007/978-1-59259-778-9_5
- Sorrels, J.; Baynham, A.; Randall, D. D.; Laxton, R. Wet and Dry Scrubbers for Acid Gas Control. US Environ. Prot. Agency Sect. 5–Chapter 1–2021–122 P, 2021.
- Barbour, W.; Roy Oommen; Shareef, G. S.; Vatavuk, W. M. Wet Scrubbers for Acid Gas. In EPA Air Pollution Control Cost Manual; U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards: Research Triangle Park, NC, 2002; pp 1-1-1–57.
- Chin, T.; Tam, I.; Yin, C.-Y. Wet Scrubbing Process with Oxidation and Reduction in Series for Removal of SO2 and NO from Marine Diesel Engine Exhaust. Chem. Eng. J. 2023, 464, 142299. https://doi.org/10.1016/j.cej.2023.142299
- Le, T.-C.; Hong, G.-H.; Lin, G.-Y.; Li, Z.; Pui, D. Y. H.; Liou, Y.-L.; Wang, B.-T.; Tsai, C.-J. Honeycomb Wet Scrubber for Acidic Gas Control: Modeling and Long-Term Test Results. Sustain. Environ. Res. 2021, 31 (1), 21. https://doi.org/10.1186/s42834-021-00094-8
- Ma, S. C.; Xu, F.; Li, D.; Fan, S.; Xu, D.; Ma, C. ORP as Slurry Oxidation Index and Model Modification in Wet Desulfurization System. J. Air Waste Manag. Assoc. 2020, 70 (8), 765–774. https://doi.org/10.1080/10962247.2020.1769771
- Liu, F.; Fiencke, C.; Guo, J.; Rieth, R.; Cuhls, C.; Dong, R.; Pfeiffer, E.-M. Bioscrubber Treatment of Exhaust Air from Intensive Pig Production: Case Study in Northern Germany at Mild Climate Condition. Eng. Life Sci. 2017, 17 (4), 458–466. https://doi.org/10.1002/elsc.201600169
- Abdel-Monaem Zytoon, M.; Ahmad AlZahrani, A.; Hamed Noweir, M.; Ahmed El-Marakby, F. Bioconversion of High Concentrations of Hydrogen Sulfide to Elemental Sulfur in Airlift Bioreactor. Sci. World J. 2014, 2014 (1), 675673. https://doi.org/10.1155/2014/675673
- Bioscrubber | EMIS. https://emis.vito.be/en/bat/tools-overview/sheets/bioscrubber (accessed 2026-08-28).
- Liu, F.; Fiencke, C.; Guo, J.; Rieth, R.; Dong, R.; Pfeiffer, E.-M. Performance Evaluation and Optimization of Field-Scale Bioscrubbers for Intensive Pig House Exhaust Air Treatment in Northern Germany. Sci. Total Environ. 2017, 579, 694–701. https://doi.org/10.1016/j.scitotenv.2016.11.039
- U.S. Environmental Protection Agency. Air Pollution Control Technology Fact Sheet: Impingement-Plate/Tray-Tower Scrubber; EPA-452/F-03-012; U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards, 2003. View EPA Fact Sheet
- Perry, J. H. Chemical Engineers’ Handbook. J. Chem. Educ. 1950, 27 (9), 533. https://doi.org/10.1021/ed027p533.1
- Treybal, R. E. Mass Transfer Operations. N. Y. 1980, 466, 493–497.
- World Chlorine Council. Chlorine Safety Scrubbing Systems; World Chlorine Council, 2011. View Publication (accessed 2026-08-28).
- Schnelle Jr, K. B.; Brown, C. A. Air Pollution Control Technology Handbook; CRC Press: Boca Raton, 2016. https://doi.org/10.1201/9781420036435
- Córdoba, P. Status of Flue Gas Desulphurisation (FGD) Systems from Coal-Fired Power Plants: Overview of the Physic-Chemical Control Processes of Wet Limestone FGDs. Fuel 2015, 144, 274–286. https://doi.org/10.1016/j.fuel.2014.12.065
- U.S. Environmental Protection Agency. Air Pollution Control Technology Fact Sheet: Venturi Scrubber; EPA-452/F-03-017; U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards, 2003. View EPA Fact Sheet
- Maximilian Lackner. TUNABLE DIODE LASER ABSORPTION SPECTROSCOPY (TDLAS) IN THE PROCESS INDUSTRIES – A REVIEW. Rev. Chem. Eng. 2007, 23 (2), 65–147. https://doi.org/10.1515/REVCE.2007.23.2.65