Duo Syringe Pump
Two Drives. More Possibilities.
The Hamilton Duo Syringe Pump gives researchers independent control over two syringe drives from a single intuitive touchscreen, delivering ±0.25% accuracy across applications from microfluidics to analytical chemistry.
Innovative Design for Maximum Performance
The Hamilton Duo Syringe Pump combines a modern design with practical features that support flexible operation and clear process visibility.
Two Independently Controlled Drives
Configure each drive's syringe size, flow parameters, and aspirate/dispense volumes independently to enable parallel processes and coordinated dual-channel methods.
Engineered Precision for Long-Lasting Performance
As the manufacturer of both syringes and pumps, Hamilton ensures precise barrel-to-plunger alignment along the drive axis, minimizing lateral stress to protect against premature wear and support long-term operation.
Up to Four Flexible Syringe Configurations
Interchangeable holders let each drive be configured for one syringe or two in tandem, with the dual-syringe holder providing synchronized dispense and withdrawal.
Progress and Status LED Indication
An integrated LED status bar provides immediate visual feedback on the pump's active, paused, completed, or attention-required status, enabling easy identification of workflow progress.
Integrated Touchscreen Control
All setup and monitoring is available directly on the instrument, with a structured interface keeping both channels separate yet accessible.
Optimized for Hamilton Syringes
The Hamilton Duo Syringe Pump is optimized for use with Hamilton syringes, delivering a precise mechanical fit and consistent liquid handling performance. A broad selection of syringe volumes and terminations lets you configure the system for a wide range of applications. Compatible syringe volumes range from 0.5 μL to 50 mL.
Adaptable Syringe Compatibility
Application requirements vary, and so do syringe preferences. In addition to Hamilton syringes, the Hamilton Duo Syringe Pump supports selected third-party syringes with compatible dimensions, flange and plunger geometry, materials, and operating characteristics.
*Recommended Compatibility Statement: For reliable performance, use Hamilton syringes or compatible third-party syringes that meet the dimensional, mechanical and material requirements specified in the product documentation. The user is responsible for verifying the suitability of the complete fluidic setup for the intended use.
Versatile Solution for Advanced Workflows
Whether delivering reagents, generating controlled flow, or automating repeatable dispensing workflows, the Hamilton Duo Syringe Pump provides the precision, flexibility, and independent channel control required for a wide range of complex workflows.
Analytical Chemistry
Microfluidics and Organ-on-a-Chip Research
Chemical Synthesis and Materials Research
Preclinical and Physiological Research
One pump. Two orientations.
Vertical Configuration
Maximize your bench space while making bubble removal quick and easy. The adaptive touchscreen automatically rotates to enusure uncompromised control.
Horizontal Configuration
A familiar benchtop layout, ideal for routine operation and frequent syringe changes.
Intuitive User Interface Simplifying Operation
The Hamilton Duo Syringe Pump graphical user interface (GUI) simplifies dual-channel liquid delivery with guided setup, real-time monitoring, and custom methods.
- Guided setup — A step-by-step window walks users through syringe selection, operating direction, flow parameters, and aspirate/dispense volumes for each drive, drawing on an integrated syringe library for accurate flow calculation.
- Real-time monitoring — Displays channel direction, status, delivered volume, progress, and elapsed or remaining time, with on-screen notifications flagging setup issues, completed runs, and abnormal conditions.
- Custom methods — Frequently performed procedures and multi-step workflows can be saved and reused, ensuring consistent operation.
Adaptable Syringe Configurations
Interchangeable single- and dual-syringe holders allow the system to be adapted to different workflows. Each drive can operate one syringe independently or move two syringes in tandem, enabling configurations with one, two, three, or four syringes. Each drive supports a single syringe up to 50 mL or two syringes up to 25 mL each when using the optional Dual-Syringe Holder.
One or Two Syringes
Three Syringes
Four Syringes
Configure for Your Application
From interchangeable syringe holders to optional fluidic modules, each accessory is designed to extend the pump’s functionality while maintaining the same intuitive operation and precise liquid handling.
Order Your Hamilton Duo Syringe Pump
Every unit ships with two single-syringe holders and a power cord for your country. Tell us about your setup and we'll help you pick the right syringes, tubing, and accessories.
For over 75 years, the Hamilton name has been recognized globally for its unwavering commitment to quality. That pledge extends to creating long-term customer partnerships. We're proud to offer in-depth training courses, on-site field support, custom product builds, and so much more.
Connect with a Hamilton expert to discuss solutions for your workflow. We are here to enable your success.
Request Type: