Passionate about cutting-edge automation, robotics, and laboratory technologies? Explore open positions and accelerate your career with us. Search Job Openings

3-2 Solenoid Valve with Pressure Sensor, PN: 10209837

Normally Closed (NC), 0 - 7 bar

Part # 10209837

The Solenoid Valve with Pressure Sensor (PN: 10209837) enables electronic switching between two fluid paths while monitoring pressure conditions during liquid delivery.

Receive More Information

Minimum: 1, Maximum: 1000

3-2 Solenoid Valve with Pressure Sensor, PN: 10209837 Details

Hamilton's Solenoid Valve with Pressure Sensor (PN: 10209837) is an optional accessory for the Duo Syringe Pump that combines automated fluid routing with integrated pressure monitoring. The 3-2-way, normally closed valve electronically switches between two flow paths, reducing the need for manual valve handling during filling, dispensing, and repeated liquid-transfer procedures. 

The integrated pressure sensor monitors pressure in the fluidic path and provides information when a defined pressure condition is reached. This helps users identify restrictions, excessive back pressure, or other changes that could affect liquid delivery. The valve operates within a pressure range of 0 to 7 bar and is compatible with 2.5 mL, 5 mL, 10 mL, 25 mL, and 50 mL syringes.

Switch between fluid paths without manually changing connections.

Identify pressure changes that may affect liquid delivery.

3-2 Solenoid Valve with Pressure Sensor, PN: 10209837 Specifications

Print
Valve Model (Solenoid Valve) 3-2, normally closed (NC)
Flow Paths (Solenoid Valve) IN → Port 2 (default), IN → Port 3 (energized)
Operating Pressure (Solenoid Valve) 0 - 7 bar
Media (Solenoid Valve) Filtered air (5 µm)/ compatible liquids
Wetted Materials (Solenoid Valve) PEEK, PVDF, FKM
Syringe Connection (Solenoid Valve) Bubble Free Prime™ (BFP, 5/16"-28), UNEF
Ports (Solenoid Valve) IN (5/16’’- 28 UNEF), Port 2, Port 3
Compatible Syringes Volume (Solenoid Valve) 2.5 mL/ 5 mL/ 10 mL/ 25 mL/ 50 mL
Voltage (Solenoid Valve) 24 V DC
Power (Solenoid Valve) 1 W
Duty Cycle (Solenoid Valve) 100%
Operating Temperature 4°C to 40°C
Storage Temperature -10°C to 70°C
Operating Humidity Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40 °C
Storage Humidity 20% to 80% RH, non-condensing
Total Internal Volume (Solenoid Valve) 518 µL
Dead Volume (Solenoid Valve) ~200 µL (sensor cavity + internal pockets outside main flow path)
Swept Volume (Solenoid Valve) ~300 µL (active flow path: ports + valve + internal channels)
Pressure Sensor Range (Solenoid Valve) 0 - 10 bar
Pressure Sensor Accuracy (Solenoid Valve) ±0.25% FSS
Pressure Sensor Output (Solenoid Valve) Digital (I²C)
Compliance Reach & RoHS
Backed by world-class service and support.

For over 75 years, the Hamilton name has been recognized globally for its unwavering commitment to quality. That pledge extends to creating long-term customer partnerships. We're proud to offer in-depth training courses, on-site field support, custom product builds, and so much more.

Let's Talk

Connect with a Hamilton expert to discuss solutions for your workflow. We are here to enable your success.

Request Type: