Arc Module Incyte-P SU for Cell Density Sensor
Arc Module Incyte-W SU for Cell Density Sensor
Incyte Arc Viable Cell Density sensor
Cell Density Sensor - Incyte Arc
Cell Density Sensor - Incyte Arc
Cell Density Sensor - Incyte Arc
Incyte P SU - conductivity probe
Incyte P SU - conductivity probe
Hamilton permittivity simulator, cylindrical metal body with multi-pin connector, labeled "Simulator," PN 243743
Arc Module Incyte-P SU

The Arc Module Incyte-P SU enables seamless integration of Incyte-P SU single-use viable cell density sensors with bioreactor control systems by converting data to Modbus RTU or 4-20 mA signals, offering both wired and wireless connectivity for real-time insights and data-driven process optimization.

Arc Module Incyte-W SU

The Arc Module Incyte-W, in combination with the Incyte-W SU, enables real-time, in-situ measurement of viable cells in wave bags. This allows for the detection and response of events in real time without the need for offline sampling.

Incyte Arc Expert - 120

The Incyte Arc Expert sensor enables in-line, real-time viable cell density measurement, essential for achieving data-driven process optimization and control in bioprocessing.

Incyte Arc Expert - 220

The Incyte Arc Expert sensor enables in-line, real-time viable cell density measurement, essential for achieving data-driven process optimization and control in bioprocessing.

Incyte Arc Expert - 320

The Incyte Arc Expert sensor enables in-line, real-time viable cell density measurement, essential for achieving data-driven process optimization and control in bioprocessing.

Incyte Arc Expert - 420

The Incyte Arc Expert sensor enables in-line, real-time viable cell density measurement, essential for achieving data-driven process optimization and control in bioprocessing.

Incyte-P SU

Hamilton's Incyte-P SU sensor element provides a cost-effective, viable cell density measurement solution for integration into single-use containers. It offers a perfect balance between high reliability and affordability, utilizing proven sensor technology from traditional sensors.

Incyte-PO SU

Hamilton Incyte-PO SU sensor element provides a cost-effective, viable cell density measurement solution for integration into single-use containers. It is optimized for welding to bag films and offers a perfect balance between high reliability and affordability, utilizing proven sensor technology from traditional sensors.

Permittivity Simulator

An electrical cap used to check the integrity of the Incyte pre-amplifier during the validation and calibration routine. This product is discontinued. Find alternative products in the Product Comparison below.

Electrical Connector VP8
Electrical Connector VP8
Electrical Connector VP8
Electrical Connector VP8
Electrical Connector VP8
Electrical Connector VP8
Electrical Connector —
Electrical Connector —
Electrical Connector —
Parameter Viable Cell Density
Parameter Viable Cell Density
Parameter Viable Cell Density
Parameter Viable Cell Density
Parameter Viable Cell Density
Parameter Viable Cell Density
Parameter —
Parameter —
Parameter —
Measuring Range 0 to 700 pF/cm, equivalent to 5 x 10^5 to 8 x 10^9 cells/mL (mammalian)
Measuring Range 0 to 700 pF/cm, equivalent to 5 x 10^5 to 8 x 10^9 cells/mL (mammalian)
Measuring Range 0 to 700 pF/cm, equivalent to 5 x 10^5 to 8 x 10^9 cells/mL (mammalian)
Measuring Range 0 to 700 pF/cm, equivalent to 5 x 10^5 to 8 x 10^9 cells/mL (mammalian)
Measuring Range 0 to 700 pF/cm, equivalent to 5 x 10^5 to 8 x 10^9 cells/mL (mammalian)
Measuring Range 0 to 700 pF/cm, equivalent to 5 x 10^5 to 8 x 10^9 cells/mL (mammalian)
Measuring Range Permittivity: 0 to 700 pF/cm, equivalent to 5 x 10^5 to 8 x 10^9 cells/mL (mammalian)
Conductivity: 1 to 50 mS/cm
Measuring Range Permittivity: 0 to 700 pF/cm, equivalent to 5 x 10^5 to 8 x 10^9 cells/mL (mammalian)
Conductivity: 1 to 50 mS/cm
Measuring Range —
Temperature Sensor Yes (on sensor element: Incyte-P SU)
Temperature Sensor Yes (on sensor element: Incyte-P SU)
Temperature Sensor Yes
Temperature Sensor Yes
Temperature Sensor Yes
Temperature Sensor Yes
Temperature Sensor —
Temperature Sensor —
Temperature Sensor —
Configurable Values VCD, Conductivity, Temperature
Configurable Values VCD, Conductivity, Temperature
Configurable Values VCD, Conductivity, Temperature
Configurable Values VCD, Conductivity, Temperature
Configurable Values VCD, Conductivity, Temperature
Configurable Values VCD, Conductivity, Temperature
Configurable Values —
Configurable Values —
Configurable Values —
Digital Interface RS485 Modbus (max. 32 addresses)
Digital Interface RS485 Modbus (max. 32 addresses)
Digital Interface RS485 Modbus (max. 32 addresses)
Digital Interface RS485 Modbus (max. 32 addresses)
Digital Interface RS485 Modbus (max. 32 addresses)
Digital Interface RS485 Modbus (max. 32 addresses)
Digital Interface —
Digital Interface —
Digital Interface —
Baud Rate 4800, 9600, 19200, 38400, 57600, 115200 Bd
Baud Rate 4800, 9600, 19200, 38400, 57600, 115200 Bd
Baud Rate 19200, 38400, 57600,115200 Bd
Baud Rate 19200, 38400, 57600,115200 Bd
Baud Rate 19200, 38400, 57600,115200 Bd
Baud Rate 19200, 38400, 57600,115200 Bd
Baud Rate —
Baud Rate —
Baud Rate —
Operating Voltage 24 V (± 10 %)
Operating Voltage 24 V (± 10 %)
Operating Voltage 24 V (± 10 %)
Operating Voltage 24 V (± 10 %)
Operating Voltage 24 V (± 10 %)
Operating Voltage 24 V (± 10 %)
Operating Voltage —
Operating Voltage —
Operating Voltage —
Sensor Output Arc: Modbus
Sensor Output Arc: Modbus
Sensor Output Arc: Modbus
Sensor Output Arc: Modbus
Sensor Output Arc: Modbus
Sensor Output Arc: Modbus
Sensor Output Electrical resistivity
Permittivity (Viable Cell Density)
NTC 22 kOhm (temperature resistor)
Sensor Output Electrical resistivity
Permittivity (Viable Cell Density)
NTC 22 kOhm (temperature resistor)
Sensor Output —
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number —
Serial Number —
Serial Number —
Certificate Yes
Certificate Yes
Certificate Yes
Certificate Yes
Certificate Yes
Certificate Yes
Certificate —
Certificate —
Certificate —
Autoclavable No
Autoclavable No
Autoclavable Yes (30-minute sterilization duration, for Revision 00: 130°C, for Revision ≥ 01: 140°C)
Autoclavable Yes (30-minute sterilization duration, for Revision 00: 130°C, for Revision ≥ 01: 140°C)
Autoclavable Yes (30-minute sterilization duration, for Revision 00: 130°C, for Revision ≥ 01: 140°C)
Autoclavable Yes (30-minute sterilization duration, for Revision 00: 130°C, for Revision ≥ 01: 140°C)
Autoclavable —
Autoclavable —
Autoclavable —
Steam Sterilizable No
Steam Sterilizable No
Steam Sterilizable Yes (140°C, 30-minute sterilization duration)
Steam Sterilizable Yes (140°C, 30-minute sterilization duration)
Steam Sterilizable Yes (140°C, 30-minute sterilization duration)
Steam Sterilizable Yes (140°C, 30-minute sterilization duration)
Steam Sterilizable —
Steam Sterilizable —
Steam Sterilizable —
CIP No
CIP No
CIP Yes (3% NaOH, 90°C, 30-minute cleaning duration)
CIP Yes (3% NaOH, 90°C, 30-minute cleaning duration)
CIP Yes (3% NaOH, 90°C, 30-minute cleaning duration)
CIP Yes (3% NaOH, 90°C, 30-minute cleaning duration)
CIP —
CIP —
CIP —
Gamma Irradiatable No
Gamma Irradiatable No
Gamma Irradiatable —
Gamma Irradiatable —
Gamma Irradiatable —
Gamma Irradiatable —
Gamma Irradiatable —
Gamma Irradiatable —
Gamma Irradiatable —
X-Ray irradiatable No
X-Ray irradiatable No
X-Ray irradiatable —
X-Ray irradiatable —
X-Ray irradiatable —
X-Ray irradiatable —
X-Ray irradiatable —
X-Ray irradiatable —
X-Ray irradiatable —
Operating Temperature Range 0 to 60 °C
Operating Temperature Range 0 to 60 °C
Operating Temperature Range 0 to 60 °C
Operating Temperature Range 0 to 60 °C
Operating Temperature Range 0 to 60 °C
Operating Temperature Range 0 to 60 °C
Operating Temperature Range 4 to 50 °C
Operating Temperature Range 4 to 50 °C
Operating Temperature Range —
Conductivity Range 1 to 50 mS/cm
Conductivity Range 1 to 50 mS/cm
Conductivity Range 1 to 80 mS/cm for firmware below CDCUM003
0.5 to 80 mS/cm for firmware CDCUM003 and above (with Hamilton calibration)
Conductivity Range 1 to 80 mS/cm for firmware below CDCUM003
0.5 to 80 mS/cm for firmware CDCUM003 and above (with Hamilton calibration)
Conductivity Range 1 to 80 mS/cm for firmware below CDCUM003
0.5 to 80 mS/cm for firmware CDCUM003 and above (with Hamilton calibration)
Conductivity Range 1 to 80 mS/cm for firmware below CDCUM003
0.5 to 80 mS/cm for firmware CDCUM003 and above (with Hamilton calibration)
Conductivity Range —
Conductivity Range —
Conductivity Range —
Protection Rating IP64 (when connected to the sensor element: Incyte-P SU)
Protection Rating IP64 (when connected to the sensor element: Incyte-P SU)
Protection Rating —
Protection Rating —
Protection Rating —
Protection Rating —
Protection Rating —
Protection Rating —
Protection Rating —
Precision at 25 °C —
Precision at 25 °C —
Precision at 25 °C Permittivity (at 1 MHz): ± 1 pF or ± 1 %
Whichever value is greater over the entire measuring range
Precision at 25 °C Permittivity (at 1 MHz): ± 1 pF or ± 1 %
Whichever value is greater over the entire measuring range
Precision at 25 °C Permittivity (at 1 MHz): ± 1 pF or ± 1 %
Whichever value is greater over the entire measuring range
Precision at 25 °C Permittivity (at 1 MHz): ± 1 pF or ± 1 %
Whichever value is greater over the entire measuring range
Precision at 25 °C Permittivity (at 1 MHz): ± 1 pF or ± 1 %
Whichever value is greater over the entire measuring range
Precision at 25 °C Permittivity (at 1 MHz): ± 1 pF or ± 1 %
Whichever value is greater over the entire measuring range
Precision at 25 °C —
Accuracy at 25 °C —
Accuracy at 25 °C —
Accuracy at 25 °C Conductivity (at 0 pF): ± 25 µS or ± 1 %
Whichever value is greater over the entire measuring range
Accuracy at 25 °C Conductivity (at 0 pF): ± 25 µS or ± 1 %
Whichever value is greater over the entire measuring range
Accuracy at 25 °C Conductivity (at 0 pF): ± 25 µS or ± 1 %
Whichever value is greater over the entire measuring range
Accuracy at 25 °C Conductivity (at 0 pF): ± 25 µS or ± 1 %
Whichever value is greater over the entire measuring range
Accuracy at 25 °C Conductivity (at 0 pF): ± 3 %
Over the entire measuring range
Accuracy at 25 °C Conductivity (at 0 pF): ± 3 %
Over the entire measuring range
Accuracy at 25 °C —
O-ring Material —
O-ring Material —
O-ring Material See compliance details in Material Specification document
O-ring Material See compliance details in Material Specification document
O-ring Material See compliance details in Material Specification document
O-ring Material See compliance details in Material Specification document
O-ring Material —
O-ring Material —
O-ring Material —
Surface Quality of Steel —
Surface Quality of Steel —
Surface Quality of Steel Ra < 0.4 µm (N5)
Surface Quality of Steel Ra < 0.4 µm (N5)
Surface Quality of Steel Ra < 0.4 µm (N5)
Surface Quality of Steel Ra < 0.4 µm (N5)
Surface Quality of Steel —
Surface Quality of Steel —
Surface Quality of Steel —
Wetted Parts —
Wetted Parts —
Wetted Parts Stainless Steel 1.4435
PEEK (Polyetheretherketone)
Platinum
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
PEEK (Polyetheretherketone)
Platinum
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
PEEK (Polyetheretherketone)
Platinum
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
PEEK (Polyetheretherketone)
Platinum
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts Platinum
Glass / Ceramic
HDPE (High Density Polyethylene)
See compliance details in Material Specification document
Wetted Parts Platinum
Glass / Ceramic
HDPE (High Density Polyethylene)
TPE-O (LDPE) (Thermoplastic Elastomer Olefinic Base)
See compliance details in Material Specification document
Wetted Parts —
Process Connection —
Process Connection —
Process Connection PG13,5
Process Connection PG13,5
Process Connection PG13,5
Process Connection PG13,5
Process Connection —
Process Connection —
Process Connection —
Diameter —
Diameter —
Diameter 12 mm
Diameter 12 mm
Diameter 12 mm
Diameter 12 mm
Diameter —
Diameter —
Diameter —
Pressure Range bar g —
Pressure Range bar g —
Pressure Range bar g 0 to 12 bar
Pressure Range bar g 0 to 12 bar
Pressure Range bar g 0 to 12 bar
Pressure Range bar g 0 to 12 bar
Pressure Range bar g —
Pressure Range bar g —
Pressure Range bar g —
Resolution at 25 °C —
Resolution at 25 °C —
Resolution at 25 °C 0.1 pF/cm
Resolution at 25 °C 0.1 pF/cm
Resolution at 25 °C 0.1 pF/cm
Resolution at 25 °C 0.1 pF/cm
Resolution at 25 °C —
Resolution at 25 °C —
Resolution at 25 °C —
Max. Accuracy —
Max. Accuracy —
Max. Accuracy Conductivity (at 0 pF): ± 100 µS (for whole operating temperature range)
Max. Accuracy Conductivity (at 0 pF): ± 100 µS (for whole operating temperature range)
Max. Accuracy Conductivity (at 0 pF): ± 100 µS (for whole operating temperature range)
Max. Accuracy Conductivity (at 0 pF): ± 100 µS (for whole operating temperature range)
Max. Accuracy —
Max. Accuracy —
Max. Accuracy —
Max. Precision —
Max. Precision —
Max. Precision Permittivity (over all frequencies): ± 1 pF (for whole operating temperature range)
Max. Precision Permittivity (over all frequencies): ± 1 pF (for whole operating temperature range)
Max. Precision Permittivity (over all frequencies): ± 1 pF (for whole operating temperature range)
Max. Precision Permittivity (over all frequencies): ± 1 pF (for whole operating temperature range)
Max. Precision —
Max. Precision —
Max. Precision —
a-length —
a-length —
a-length 120 mm
a-length 220 mm
a-length 320 mm
a-length 420 mm
a-length —
a-length —
a-length —
Drift at 25 °C —
Drift at 25 °C —
Drift at 25 °C —
Drift at 25 °C —
Drift at 25 °C —
Drift at 25 °C —
Drift at 25 °C No observable drift
Drift at 25 °C No observable drift
Drift at 25 °C —
Wet-in Time —
Wet-in Time —
Wet-in Time —
Wet-in Time —
Wet-in Time —
Wet-in Time —
Wet-in Time < 30 min (after dry storage)
Wet-in Time < 30 min (after dry storage)
Wet-in Time —
Response Time at 25 °C —
Response Time at 25 °C —
Response Time at 25 °C —
Response Time at 25 °C —
Response Time at 25 °C —
Response Time at 25 °C —
Response Time at 25 °C t98% < 30 s (conductivity: 1.413 to 50 mS/cm)
Response Time at 25 °C t98% < 30 s (conductivity: 1.413 to 50 mS/cm)
Response Time at 25 °C —
Shelf Life —
Shelf Life —
Shelf Life —
Shelf Life —
Shelf Life —
Shelf Life —
Shelf Life 24 months before irradiation
37 months after irradiation
Shelf Life 24 months before irradiation
37 months after irradiation
Shelf Life —
Patch type —
Patch type —
Patch type —
Patch type —
Patch type —
Patch type —
Patch type Legacy (See drawing)
Patch type Overmold (See drawing)
Patch type —
Burst Pressure —
Burst Pressure —
Burst Pressure —
Burst Pressure —
Burst Pressure —
Burst Pressure —
Burst Pressure Up to 10 barg
Burst Pressure Up to 10 barg
Burst Pressure —
Storage Temperature Range —
Storage Temperature Range —
Storage Temperature Range —
Storage Temperature Range —
Storage Temperature Range —
Storage Temperature Range —
Storage Temperature Range 4 to 40 °C in non-condensing environment (<85% r. H.)
Storage Temperature Range 4 to 40 °C in non-condensing environment (<85% r. H.)
Storage Temperature Range —
Transport Temperature Range —
Transport Temperature Range —
Transport Temperature Range —
Transport Temperature Range —
Transport Temperature Range —
Transport Temperature Range —
Transport Temperature Range -30 to 60 °C (according to ASTM D4169-13)
Transport Temperature Range -30 to 60 °C (according to ASTM D4169-13)
Transport Temperature Range —
Sterilization —
Sterilization —
Sterilization —
Sterilization —
Sterilization —
Sterilization —
Sterilization Gamma irradiation compatible (up to 50 kGy)
X-Ray irradiation compatible (up to 50 kGy)
Not validated for autoclavation, Sterilization In Place (SIP), nor Cleaning In Place (CIP)
Sterilization Gamma irradiation compatible (up to 50 kGy)
X-Ray irradiation compatible (up to 50 kGy)
Not validated for autoclavation, Sterilization In Place (SIP), nor Cleaning In Place (CIP)
Sterilization —
Chemical Resistance —
Chemical Resistance —
Chemical Resistance —
Chemical Resistance —
Chemical Resistance —
Chemical Resistance —
Chemical Resistance See Chemical Resistance Guide
Chemical Resistance See Chemical Resistance Guide
Chemical Resistance —