Compare Products

Conductivity Sensor Conducell 4USF
Conductivity Sensor Conducell 4USF
Conductivity Sensor Conducell 4USF
Conducell 4UxF analog sensor
Conducell 4UxF analog sensor
Conducell 4UxF analog sensor
Conductivity Sensor Conducell 4USF
Conductivity Sensor Conducell 4USF
Conductivity Sensor Conducell 4USF
Conducell 4UxF analog sensor
Conducell 4UxF analog sensor
Conducell 4UxF analog sensor
Conducell 4USF VP 30

The FDA-certified Conducell 4USF VP 4-pole conductivity sensor, featuring stable Stainless steel electrodes and a VP6 connector offering PG13.5, VariVent, or Bioconnect options, provides precise and linear conductivity measurements across a broad range in biopharma applications.

Conducell 4USF VP 60

The FDA-certified Conducell 4USF VP 4-pole conductivity sensor, featuring stable Stainless steel electrodes and a VP6 connector offering PG13.5, VariVent, or Bioconnect options, provides precise and linear conductivity measurements across a broad range in biopharma applications.

Conducell 4USF VP 120

The FDA-certified Conducell 4USF VP 4-pole conductivity sensor, featuring stable Stainless steel electrodes and a VP6 connector offering PG13.5, VariVent, or Bioconnect options, provides precise and linear conductivity measurements across a broad range in biopharma applications.

Conducell 4USF VP 225

The FDA-certified Conducell 4USF VP 4-pole conductivity sensor, featuring stable Stainless steel electrodes and a VP6 connector offering PG13.5, VariVent, or Bioconnect options, provides precise and linear conductivity measurements across a broad range in biopharma applications.

Conducell 4USF VP 325

The FDA-certified Conducell 4USF VP 4-pole conductivity sensor, featuring stable Stainless steel electrodes and a VP6 connector offering PG13.5, VariVent, or Bioconnect options, provides precise and linear conductivity measurements across a broad range in biopharma applications.

Conducell 4USF VP 425

The FDA-certified Conducell 4USF VP 4-pole conductivity sensor, featuring stable Stainless steel electrodes and a VP6 connector offering PG13.5, VariVent, or Bioconnect options, provides precise and linear conductivity measurements across a broad range in biopharma applications.

Conducell 4UPTF VP 30

The Conducell 4UPTF VP is an FDA-certified, hygienic 4-pole conductivity sensor (1 µS/cm–500 mS/cm) with CIP, SIP, and autoclave compatibility—ideal for reliable, accurate measurements when paired with a conductivity transmitter.

Conducell 4UPTF VP 60

The Conducell 4UPTF VP is an FDA-certified, hygienic 4-pole conductivity sensor (1 µS/cm–500 mS/cm) with CIP, SIP, and autoclave compatibility—ideal for reliable, accurate measurements when paired with a conductivity transmitter.

Conducell 4UPtF VP 120

The Conducell 4UPTF VP is an FDA-certified, hygienic 4-pole conductivity sensor (1 µS/cm–500 mS/cm) with CIP, SIP, and autoclave compatibility—ideal for reliable, accurate measurements when paired with a conductivity transmitter.

Conducell 4UPtF VP 225

The Conducell 4UPTF VP is an FDA-certified, hygienic 4-pole conductivity sensor (1 µS/cm–500 mS/cm) with CIP, SIP, and autoclave compatibility—ideal for reliable, accurate measurements when paired with a conductivity transmitter.

Conducell 4UPtF VP 325

The Conducell 4UPTF VP is an FDA-certified, hygienic 4-pole conductivity sensor (1 µS/cm–500 mS/cm) with CIP, SIP, and autoclave compatibility—ideal for reliable, accurate measurements when paired with a conductivity transmitter.

Conducell 4UPtF VP 425

The Conducell 4UPTF VP is an FDA-certified, hygienic 4-pole conductivity sensor (1 µS/cm–500 mS/cm) with CIP, SIP, and autoclave compatibility—ideal for reliable, accurate measurements when paired with a conductivity transmitter.

Wetted Parts Stainless Steel 1.4435
PEEK (Polyetheretherketone)
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
PEEK (Polyetheretherketone)
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
PEEK (Polyetheretherketone)
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
PEEK (Polyetheretherketone)
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
PEEK (Polyetheretherketone)
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
PEEK (Polyetheretherketone)
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts PEEK (Polyetheretherketone)
Platinum
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts PEEK (Polyetheretherketone)
Platinum
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts PEEK (Polyetheretherketone)
Platinum
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts PEEK (Polyetheretherketone)
Platinum
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts PEEK (Polyetheretherketone)
Platinum
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts PEEK (Polyetheretherketone)
Platinum
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Electrical Connector VP6
Electrical Connector VP6
Electrical Connector VP6
Electrical Connector VP6
Electrical Connector VP6
Electrical Connector VP6
Electrical Connector VP6
Electrical Connector VP6
Electrical Connector VP6
Electrical Connector VP6
Electrical Connector VP6
Electrical Connector VP6
Measuring Range 1 µS/cm to 500 mS/cm
Measuring Range 1 µS/cm to 500 mS/cm
Measuring Range 1 µS/cm to 500 mS/cm
Measuring Range 1 µS/cm to 500 mS/cm
Measuring Range 1 µS/cm to 500 mS/cm
Measuring Range 1 µS/cm to 500 mS/cm
Measuring Range 1 µS/cm to 500 mS/cm
Measuring Range 1 µS/cm to 500 mS/cm
Measuring Range 1 µS/cm to 500 mS/cm
Measuring Range 1 µS/cm to 500 mS/cm
Measuring Range 1 µS/cm to 500 mS/cm
Measuring Range 1 µS/cm to 500 mS/cm
Cell Constant 0.36 /cm
Cell Constant 0.36 /cm
Cell Constant 0.36 /cm
Cell Constant 0.36 /cm
Cell Constant 0.36 /cm
Cell Constant 0.36 /cm
Cell Constant 0.36 /cm
Cell Constant 0.36 /cm
Cell Constant 0.36 /cm
Cell Constant 0.36 /cm
Cell Constant 0.36 /cm
Cell Constant 0.36 /cm
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Process Connection PG13,5
Process Connection PG13,5
Process Connection PG13,5
Process Connection PG13,5
Process Connection PG13,5
Process Connection PG13,5
Process Connection PG13,5
Process Connection PG13,5
Process Connection PG13,5
Process Connection PG13,5
Process Connection PG13,5
Process Connection PG13,5
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
Diameter 12 mm
Diameter 12 mm
Diameter 12 mm
Diameter 12 mm
Diameter 12 mm
Diameter 12 mm
Diameter 12 mm
Diameter 12 mm
Diameter 12 mm
Diameter 12 mm
Diameter 12 mm
Diameter 12 mm
Autoclavable Yes
Autoclavable Yes
Autoclavable Yes
Autoclavable Yes
Autoclavable Yes
Autoclavable Yes
Autoclavable Yes
Autoclavable Yes
Autoclavable Yes
Autoclavable Yes
Autoclavable Yes
Autoclavable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
CIP Yes
CIP Yes
CIP Yes
CIP Yes
CIP Yes
CIP Yes
CIP Yes
CIP Yes
CIP Yes
CIP Yes
CIP Yes
CIP Yes
Operating Temperature Range -20 to 150 °C
Operating Temperature Range -20 to 150 °C
Operating Temperature Range -20 to 150 °C
Operating Temperature Range -20 to 150 °C
Operating Temperature Range -20 to 150 °C
Operating Temperature Range -20 to 150 °C
Operating Temperature Range -20 to 150 °C
Operating Temperature Range -20 to 150 °C
Operating Temperature Range -20 to 150 °C
Operating Temperature Range -20 to 150 °C
Operating Temperature Range -20 to 150 °C
Operating Temperature Range -20 to 150 °C
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Electrode Material Stainless steel 1.4435
Electrode Material Stainless steel 1.4435
Electrode Material Stainless steel 1.4435
Electrode Material Stainless steel 1.4435
Electrode Material Stainless steel 1.4435
Electrode Material Stainless steel 1.4435
Electrode Material Titanium
Electrode Material Titanium
Electrode Material Titanium
Electrode Material Titanium
Electrode Material Titanium
Electrode Material Titanium
a-length 30 mm
a-length 60 mm
a-length 120 mm
a-length 215 mm
a-length 325 mm
a-length 425 mm
a-length 30 mm
a-length 60 mm
a-length 120 mm
a-length 215 mm
a-length 325 mm
a-length 425 mm
Backed by world-class service and support.

For over 75 years, the Hamilton name has been recognized globally for its unwavering commitment to quality. That pledge extends to creating long-term customer partnerships. We're proud to offer in-depth training courses, on-site field support, custom product builds, and so much more.

Let's Talk

Connect with a Hamilton expert to discuss solutions for your workflow. We are here to enable your success.

Request Type: