Conducell UPW Arc PG13,5 Conductivity Sensor
Conducell UPW Arc TC 1.5" Conductivity Sensor
Conducell UPW PG 13.5 conductivity sensor
Conducell 2DC-PG Conductivity sensor
Conducell UPW Arc PG13,5

The Conducell UPW sensor provides industry-leading, accuracy and sensitivity for producing pure and ultra-pure water in the pharmaceutical industry.

Conducell UPW Arc TC 1.5"

The Conducell UPW sensor provides industry-leading, accuracy and sensitivity for producing pure and ultra-pure water in the pharmaceutical industry.

Conducell UPW PG 13,5

The Conducell UPW sensor provides industry-leading accuracy and sensitivity for producing pure and ultrapure water in the pharmaceutical industry. The sensor is USP 645, EP, JP and FDA compliant.

Conducell 2DC-PG

The Conducell 2DC-PG 2-Pole sensor is a basic low-cost sensor ideal for contaminant free processes. It's 1.0 cell constant allows for measurements from 10 to 20 mS/cm. The plastic shaft and graphite electrode are easy to clean. The 5 M fixed cable allows for easy submersion beneath the liquid surface. This product must be connected to a conductivity transmitter such as the H100.

Process Connection PG13,5
PG13,5
Process Connection PG13,5
Triclamp 1.5"
Process Connection PG13,5
Process Connection PG13,5
Sensor Family Conducell UPW
Sensor Family Conducell UPW
Sensor Family Conducell UPW
Sensor Family
Wetted Parts Stainless Steel 1.4435
PEEK (Polyetheretherketone)
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
PEEK (Polyetheretherketone)
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
PEEK (Polyetheretherketone)
EPDM (Ethylene propylene elastomer)
(FDA 21 CFR 177.2600; EU 1935/2004; USP <88> Class VI - 121 °C)
(FDA 21 CFR 177.2415; EU 1935/2004, EU 10/2011; USP <88> Class VI - 121 °C)
See compliance details in Material Specification document
Wetted Parts Graphite
EPDM (Ethylene propylene elastomer)
SAN (Polystyrene-Acrylonitrile)
(FDA 21 CFR 177.2600; EU 1935/2004; USP <88> Class VI - 121 °C)
Electrical Connector VP8
Electrical Connector VP8
Electrical Connector VP6
Electrical Connector 5 m Fix Cable / Open End
Parameter Conductivity (2-pole)
Parameter Conductivity (2-pole)
Parameter Conductivity (2-pole)
Parameter
Sensor Output Arc: Modbus, 4 to 20 mA
Sensor Output Arc: Modbus, 4 to 20 mA
Sensor Output Traditional
Sensor Output
Measuring Range 0.01 to 1500 µS/cm
Measuring Range 0.01 to 1500 µS/cm
Measuring Range 0.02 to 2000 µS/cm
Measuring Range 10 µS/cm to 20 mS/cm
Accuracy at 25 °C ± 3 %
Accuracy at 25 °C ± 3 %
Accuracy at 25 °C
Accuracy at 25 °C
Cell Constant < 0.1 / cm
Cell Constant < 0.1 / cm
Cell Constant < 0.1 / cm
Cell Constant 1/cm
Temperature Sensor NTC 22 kOhm
Temperature Sensor NTC 22 kOhm
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Configurable Values Conductivity: µS/cm, mS/cm; Temperature: °C, °F, K
Configurable Values Conductivity: µS/cm, mS/cm; Temperature: °C, °F, K
Configurable Values
Configurable Values
O-ring Material
O-ring Material
O-ring Material
O-ring Material
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel
Analog Interface 1 4 to 20 mA for conductivity, programmable
Analog Interface 1 4 to 20 mA for conductivity, programmable
Analog Interface 1
Analog Interface 1
Analog Interface 2 4 to 20 mA for Temp., programmable
Analog Interface 2 4 to 20 mA for Temp., programmable
Analog Interface 2
Analog Interface 2
Analog Interface 1 and 2 Galvanically not isolated; pulse width modulation 3.5 kHz
Analog Interface 1 and 2 Galvanically not isolated; pulse width modulation 3.5 kHz
Analog Interface 1 and 2
Analog Interface 1 and 2
Digital Interface RS485 Modbus (max. 32 addresses)
Digital Interface RS485 Modbus (max. 32 addresses)
Digital Interface
Digital Interface
Baud Rate 4800, 9600, 19200, 38400, 57600, 115200 Bd
Baud Rate 4800, 9600, 19200, 38400, 57600, 115200 Bd
Baud Rate
Baud Rate
Operating Voltage 7 to 30 VDC max. 150 mW
Operating Voltage 7 to 30 VDC max. 150 mW
Operating Voltage
Operating Voltage
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
Certificate No
ATEX Approval No
ATEX Approval No
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval No
IECEx Approval No
IECEx Approval No
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval
Autoclavable Yes, max. Temperature 130 °C
Autoclavable Yes, max. Temperature 130 °C
Autoclavable Yes
Autoclavable No
Steam Sterilizable Yes, max. Temperature 140 °C
Steam Sterilizable Yes, max. Temperature 140 °C
Steam Sterilizable Yes
Steam Sterilizable No
CIP Yes
CIP Yes
CIP Yes
CIP No
Operating Temperature Range Analog interface: 0 to 110 °C; Digital interface: 0 to 130 °C
Operating Temperature Range Analog interface: 0 to 110 °C; Digital interface: 0 to 130 °C
Operating Temperature Range -10 to 140 °C
Operating Temperature Range -5 to 80 °C
Pressure Range bar g 0 to 10 bar g (130 °C)
Pressure Range bar g 0 to 10 bar g (130 °C)
Pressure Range bar g 0 to 10 bar g (130 °C)
Pressure Range bar g 0 to 6 bar
Max. Pressure bar g 10 bar g (130 °C)
Max. Pressure bar g 10 bar g (130 °C)
Max. Pressure bar g 10 bar g (130 °C)
Max. Pressure bar g
a-length 120 mm
a-length 87 mm
a-length 120 mm
a-length 120 mm
Diameter 12 mm
Diameter 17 mm
Diameter 12 mm
Diameter 12 mm
Backed by world-class service and support.

For over 75 years, the Hamilton name has been recognized globally for its unwavering commitment to quality. That pledge extends to creating long-term customer partnerships. We're proud to offer in-depth training courses, on-site field support, custom product builds, and so much more.

Let's Talk

Connect with a Hamilton expert to discuss solutions for your workflow. We are here to enable your success.

Request Type: