The Conducell UPW sensor provides industry-leading accuracy and sensitivity for producing pure and ultrapure water in the pharmaceutical industry. The sensor is USP 645, EP, JP and FDA compliant.
The Conducell 2DC-PG 2-Pole sensor is a basic low-cost sensor ideal for contaminant free processes. It's 1.0 cell constant allows for measurements from 10 to 20 mS/cm. The plastic shaft and graphite electrode are easy to clean. The 5 M fixed cable allows for easy submersion beneath the liquid surface. This product must be connected to a conductivity transmitter such as the H100.
Process Connection
PG13,5 PG13,5
Process Connection
PG13,5 Triclamp 1.5"
Process Connection
PG13,5
Process Connection
PG13,5
Sensor Family
Conducell UPW
Sensor Family
Conducell UPW
Sensor Family
Conducell UPW
Sensor Family
—
Wetted Parts
Stainless Steel 1.4435 PEEK (Polyetheretherketone) EPDM (Ethylene propylene elastomer) See compliance details in Material Specification document
Wetted Parts
Stainless Steel 1.4435 PEEK (Polyetheretherketone) EPDM (Ethylene propylene elastomer) See compliance details in Material Specification document
Wetted Parts
Stainless Steel 1.4435 PEEK (Polyetheretherketone) EPDM (Ethylene propylene elastomer) (FDA 21 CFR 177.2600; EU 1935/2004; USP <88> Class VI - 121 °C) (FDA 21 CFR 177.2415; EU 1935/2004, EU 10/2011; USP <88> Class VI - 121 °C) See compliance details in Material Specification document
Wetted Parts
Graphite EPDM (Ethylene propylene elastomer) SAN (Polystyrene-Acrylonitrile) (FDA 21 CFR 177.2600; EU 1935/2004; USP <88> Class VI - 121 °C)
Electrical Connector
VP8
Electrical Connector
VP8
Electrical Connector
VP6
Electrical Connector
5 m Fix Cable / Open End
Parameter
Conductivity (2-pole)
Parameter
Conductivity (2-pole)
Parameter
Conductivity (2-pole)
Parameter
—
Sensor Output
Arc: Modbus, 4 to 20 mA
Sensor Output
Arc: Modbus, 4 to 20 mA
Sensor Output
Traditional
Sensor Output
—
Measuring Range
0.01 to 1500 µS/cm
Measuring Range
0.01 to 1500 µS/cm
Measuring Range
0.02 to 2000 µS/cm
Measuring Range
10 µS/cm to 20 mS/cm
Accuracy at 25 °C
± 3 %
Accuracy at 25 °C
± 3 %
Accuracy at 25 °C
—
Accuracy at 25 °C
—
Cell Constant
< 0.1 / cm
Cell Constant
< 0.1 / cm
Cell Constant
< 0.1 / cm
Cell Constant
1/cm
Temperature Sensor
NTC 22 kOhm
Temperature Sensor
NTC 22 kOhm
Temperature Sensor
Pt1000
Temperature Sensor
Pt1000
Configurable Values
Conductivity: µS/cm, mS/cm; Temperature: °C, °F, K
Configurable Values
Conductivity: µS/cm, mS/cm; Temperature: °C, °F, K
Configurable Values
—
Configurable Values
—
O-ring Material
—
O-ring Material
—
O-ring Material
—
O-ring Material
—
Surface Quality of Steel
Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel
Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel
Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel
—
Analog Interface 1
4 to 20 mA for conductivity, programmable
Analog Interface 1
4 to 20 mA for conductivity, programmable
Analog Interface 1
—
Analog Interface 1
—
Analog Interface 2
4 to 20 mA for Temp., programmable
Analog Interface 2
4 to 20 mA for Temp., programmable
Analog Interface 2
—
Analog Interface 2
—
Analog Interface 1 and 2
Galvanically not isolated; pulse width modulation 3.5 kHz
Analog Interface 1 and 2
Galvanically not isolated; pulse width modulation 3.5 kHz
Analog Interface 1 and 2
—
Analog Interface 1 and 2
—
Digital Interface
RS485 Modbus (max. 32 addresses)
Digital Interface
RS485 Modbus (max. 32 addresses)
For over 75 years, the Hamilton name has been recognized globally for its unwavering commitment to quality. That pledge extends to creating long-term customer partnerships. We're proud to offer in-depth training courses, on-site field support, custom product builds, and so much more.
Let's Talk
Connect with a Hamilton expert to discuss solutions for your workflow. We are here to enable your success.