Compare Products

Sensor Ionotrode
InchTrode N100F pH sensor
Inchtrode N75F pH Sensor
Inchtrode N75FC10 pH Sensor
InchTrode pH sensor
Inchtrode N75PC10 pH sensor
MecoTrode 120 pH Sensor
MecoTrode VP 120 pH Sensor
MecoTrode VP 120 pH Sensor
Fermotrode pH sensor
Fermotrode pH sensor
Fermotrode pH sensor
IonoTrode

The Hamilton IonoTrode pH sensor provides highly accurate and stable pH measurements in challenging low conductivity media and high purity water applications thanks to its low resistance F glass membrane and controlled electrolyte flow.

InchTrode N100F

For precise and quick pH measurement in demanding applications. The PEEK shaft and polymer electrolyte enable easy multi-angled installation of sensors into processes. The Single Pore junction offers the best accuracy and response time due to direct contact between the reference and sample.

Inchtrode N75F

For precise and quick pH measurement in demanding applications. The PEEK shaft and polymer electrolyte enable easy multi-angled installation of sensors into processes. The Single Pore junction offers the best accuracy and response time due to direct contact between the reference and sample.

Inchtrode N75FC10

For precise and quick pH measurement in demanding applications. The PEEK shaft and polymer electrolyte enable easy multi-angled installation of sensors into processes. The Single Pore junction offers the best accuracy and response time due to direct contact between the reference and sample.

Inchtrode N75P

For precise and quick pH measurement in demanding applications. The PEEK shaft and polymer electrolyte enable easy multi-angled installation of sensors into processes. The Single Pore junction offers the best accuracy and response time due to direct contact between the reference and sample.

Inchtrode N75PC10

For precise and quick pH measurement in demanding applications. The PEEK shaft and polymer electrolyte enable easy multi-angled installation of sensors into processes. The Single Pore junction offers the best accuracy and response time due to direct contact between the reference and sample.

MecoTrode 120

Hamilton’s MecoTrode pH sensors deliver stable, accurate readings in extreme pH conditions and at high temperatures. An H-glass membrane supports alkaline applications, with optional HF-glass for use in media containing hydrofluoric acid. Triple ceramic diaphragms reduce flow potential, ensuring reliable performance.

MecoTrode VP 120

Hamilton’s MecoTrode pH sensors deliver stable, accurate readings in extreme pH conditions and at high temperatures. An H-glass membrane supports alkaline applications, with optional HF-glass for use in media containing hydrofluoric acid. Triple ceramic diaphragms reduce flow potential, ensuring reliable performance.

MecoTrode H VP 225 Pt 100

Hamilton’s MecoTrode pH sensors deliver stable, accurate readings in extreme pH conditions and at high temperatures. An H-glass membrane supports alkaline applications, with optional HF-glass for use in media containing hydrofluoric acid. Triple ceramic diaphragms reduce flow potential, ensuring reliable performance.

FermoTrode 120

The maintenance-free FermoTrode pH sensor is ideal for pharmaceutical and biotech applications requiring reliable pH measurement with a clog-free design, stable performance after sterilisation, and a long sensor lifetime.

FermoTrode 150

The maintenance-free FermoTrode pH sensor is ideal for pharmaceutical and biotech applications requiring reliable pH measurement with a clog-free design, stable performance after sterilisation, and a long sensor lifetime.

FermoTrode 200

The maintenance-free FermoTrode pH sensor is ideal for pharmaceutical and biotech applications requiring reliable pH measurement with a clog-free design, stable performance after sterilisation, and a long sensor lifetime.

Wetted Parts GΙass
EPDM (Ethylene propylene elastomer)
FEP (Fluorinated Ethylene Propylene)
(FDA 21 CFR 177.2600; EU 1935/2004; USP <88> Class VI - 121 °C)
Wetted Parts GΙass
PEEK (Polyetheretherketone)
Wetted Parts GΙass
PEEK (Polyetheretherketone)
Wetted Parts GΙass
PEEK (Polyetheretherketone)
Wetted Parts GΙass
PEEK (Polyetheretherketone)
Wetted Parts GΙass
PEEK (Polyetheretherketone)
Wetted Parts GΙass
Ceramic
EPDM (Ethylene propylene elastomer)
Wetted Parts GΙass
Ceramic
EPDM (Ethylene propylene elastomer)
Wetted Parts GΙass
Ceramic
EPDM (Ethylene propylene elastomer)
Wetted Parts GΙass
Ceramic
Wetted Parts GΙass
Ceramic
Wetted Parts GΙass
Ceramic
pH Glass Hamilton Type F Glass
pH Glass Hamilton Type HF Glass
pH Glass Hamilton Type HF Glass
pH Glass Hamilton Type HF Glass
pH Glass Hamilton Type HF Glass
pH Glass Hamilton Type HF Glass
pH Glass Hamilton Type H Glass
pH Glass Hamilton Type H Glass
pH Glass Hamilton Type H Glass
pH Glass Hamilton Type PHI Glass
pH Glass Hamilton Type PHI Glass
pH Glass Hamilton Type PHI Glass
Electrical Connector S7
Electrical Connector
Electrical Connector
Electrical Connector
Electrical Connector
Electrical Connector
Electrical Connector S8
Electrical Connector VP6
Electrical Connector VP6
Electrical Connector S7
Electrical Connector S7
Electrical Connector S7
a-length 120 mm
a-length 140 mm
a-length 143 mm
a-length 143 mm
a-length 150 mm
a-length 150 mm
a-length 120 mm
a-length 120 mm
a-length 225 mm
a-length 120 mm
a-length 150 mm
a-length 200 mm
Parameter pH
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Measuring Range pH 0 to 14
Measuring Range pH 0 to 14
Measuring Range pH 0 to 14
Measuring Range pH 0 to 14
Measuring Range pH 0 to 14
Measuring Range pH 0 to 14
Measuring Range pH 0 to 14
Measuring Range pH 0 to 14
Measuring Range pH 0 to 14
Measuring Range pH 0 to 14
Measuring Range pH 0 to 14
Measuring Range pH 0 to 14
Electrolyte 3 M KCl
Electrolyte Polisolve
Electrolyte Polisolve
Electrolyte Polisolve
Electrolyte Polisolve
Electrolyte Polisolve
Electrolyte Viscous 3 M KCl-Pharma, blue
Electrolyte Viscous 3 M KCl-Pharma, blue
Electrolyte Viscous 3 M KCl-Pharma, blue
Electrolyte Skylyte
Electrolyte Skylyte
Electrolyte Skylyte
Sensitivity 57 to 59 mV / pH at 25 °C
Sensitivity 57 to 59 mV / pH at 25 °C
Sensitivity 57 to 59 mV / pH at 25 °C
Sensitivity 57 to 59 mV / pH at 25 °C
Sensitivity 57 to 59 mV / pH at 25 °C
Sensitivity 57 to 59 mV / pH at 25 °C
Sensitivity 57 to 59 mV / pH at 25 °C
Sensitivity 57 to 59 mV / pH at 25 °C
Sensitivity 57 to 59 mV / pH at 25 °C
Sensitivity 57 to 59 mV / pH at 25 °C
Sensitivity 57 to 59 mV / pH at 25 °C
Sensitivity 57 to 59 mV / pH at 25 °C
Zero Point 0 ± 20 mV
Zero Point 0 ± 20 mV
Zero Point 0 ± 20 mV
Zero Point 0 ± 20 mV
Zero Point 0 ± 20 mV
Zero Point 0 ± 20 mV
Zero Point 0 ± 20 mV
Zero Point 0 ± 20 mV
Zero Point 0 ± 20 mV
Zero Point 0 ± 20 mV
Zero Point 0 ± 20 mV
Zero Point 0 ± 20 mV
pH Glass Resistance Low
pH Glass Resistance Moderate
pH Glass Resistance Moderate
pH Glass Resistance Moderate
pH Glass Resistance Moderate
pH Glass Resistance Moderate
pH Glass Resistance Moderate
pH Glass Resistance Moderate
pH Glass Resistance Moderate
pH Glass Resistance Moderate
pH Glass Resistance Moderate
pH Glass Resistance Moderate
Membrane Shape Spherical
Membrane Shape
Membrane Shape
Membrane Shape
Membrane Shape
Membrane Shape
Membrane Shape Spherical
Membrane Shape Spherical
Membrane Shape Spherical
Membrane Shape Spherical
Membrane Shape Spherical
Membrane Shape Spherical
Diaphragm Sleeve
Diaphragm Single Pore ring
Diaphragm Single Pore ring
Diaphragm Single Pore ring
Diaphragm Single Pore ring
Diaphragm Single Pore ring
Diaphragm HP-Ceramic
Diaphragm HP-Ceramic
Diaphragm HP-Ceramic
Diaphragm Coatramic
Diaphragm Coatramic
Diaphragm Coatramic
Reference System Hamilton Everef
Reference System Hamilton Everef-L
Reference System Hamilton Everef-L
Reference System Hamilton Everef-L
Reference System Hamilton Everef-L
Reference System Hamilton Everef-L
Reference System Hamilton Everef
Reference System Hamilton Everef
Reference System Hamilton Everef
Reference System Hamilton Everef-F, Silver ion barrier included
Reference System Hamilton Everef-F, Silver ion barrier included
Reference System Hamilton Everef-F, Silver ion barrier included
Liquid Earth No
Liquid Earth Yes
Liquid Earth Yes
Liquid Earth Yes
Liquid Earth Yes
Liquid Earth Yes
Liquid Earth No
Liquid Earth No
Liquid Earth No
Liquid Earth No
Liquid Earth No
Liquid Earth No
Temperature Sensor No
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Temperature Sensor Pt100
Temperature Sensor Pt1000
Temperature Sensor Pt100
Temperature Sensor No
Temperature Sensor Pt100
Temperature Sensor Pt100
Temperature Sensor No
Temperature Sensor No
Temperature Sensor No
O-ring Material FDA 21 CFR 177.2600; EC 1935/2004; USP <87>; USP <88> Class VI (121 °C)
O-ring Material
O-ring Material
O-ring Material
O-ring Material
O-ring Material
O-ring Material FDA 21 CFR 177.2600; EC 1935/2004; USP <87>; USP <88> Class VI (121 °C)
O-ring Material FDA 21 CFR 177.2600; EC 1935/2004; USP <87>; USP <88> Class VI (121 °C)
O-ring Material FDA 21 CFR 177.2600; EC 1935/2004; USP <87>; USP <88> Class VI (121 °C)
O-ring Material
O-ring Material
O-ring Material
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Recommended Storage Hamilton Storage Solution or 3 M KCl
Recommended Storage Hamilton Storage Solution or 3 M KCl
Recommended Storage Hamilton Storage Solution or 3 M KCl
Recommended Storage Hamilton Storage Solution or 3 M KCl
Recommended Storage Hamilton Storage Solution or 3 M KCl
Recommended Storage Hamilton Storage Solution or 3 M KCl
Recommended Storage Hamilton Storage Solution or 3 M KCl
Recommended Storage Hamilton Storage Solution or 3 M KCl
Recommended Storage Hamilton Storage Solution or 3 M KCl
Recommended Storage Hamilton Storage Solution or 3 M KCl
Recommended Storage Hamilton Storage Solution or 3 M KCl
Recommended Storage Hamilton Storage Solution or 3 M KCl
Certificate No
Certificate No
Certificate No
Certificate No
Certificate No
Certificate No
Certificate Yes, with measured values in Buffer pH 4.01 and pH 7.00
Certificate Yes, with measured values in Buffer pH 4.01 and pH 7.00
Certificate Yes, with measured values in Buffer pH 4.01 and pH 7.00
Certificate No
Certificate No
Certificate No
Diameter 12 mm
Diameter
Diameter
Diameter
Diameter
Diameter
Diameter 12 mm
Diameter 12 mm
Diameter 12 mm
Diameter 30 mm
Diameter 30 mm
Diameter 30 mm
Steam Sterilizable No
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable No
Steam Sterilizable No
Steam Sterilizable No
Steam Sterilizable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
CIP No
CIP No
CIP No
CIP No
CIP No
CIP No
CIP No
CIP No
CIP No
CIP No
CIP No
CIP No
Operating Temperature Range -10 to 40 °C
Operating Temperature Range -10 to 125 °C
Operating Temperature Range -10 to 125 °C
Operating Temperature Range -10 to 125 °C
Operating Temperature Range -10 to 125 °C
Operating Temperature Range -10 to 125 °C
Operating Temperature Range 0 to 130 °C
Operating Temperature Range 0 to 130 °C
Operating Temperature Range 0 to 130 °C
Operating Temperature Range 0 to 130 °C
Operating Temperature Range 0 to 130 °C
Operating Temperature Range 0 to 130 °C
Sample min Conductivity 0.2 µS/cm
Sample min Conductivity 2 µS/cm
Sample min Conductivity 2 µS/cm
Sample min Conductivity 2 µS/cm
Sample min Conductivity 2 µS/cm
Sample min Conductivity 2 µS/cm
Sample min Conductivity 50 µS/cm
Sample min Conductivity 50 µS/cm
Sample min Conductivity 50 µS/cm
Sample min Conductivity 50 µS/cm
Sample min Conductivity 50 µS/cm
Sample min Conductivity 50 µS/cm
Pressure Range bar g 0 to 0.5 bar (higher if side-arm is pressurized)
Pressure Range bar g 0 to 10 bar at 25 °C, 0 to 6 bar at 130 °C
Pressure Range bar g 0 to 10 bar at 25 °C, 0 to 6 bar at 130 °C
Pressure Range bar g 0 to 10 bar at 25 °C, 0 to 6 bar at 130 °C
Pressure Range bar g 0 to 10 bar at 25 °C, 0 to 6 bar at 130 °C
Pressure Range bar g 0 to 10 bar at 25 °C, 0 to 6 bar at 130 °C
Pressure Range bar g 0 to 16 bar at 25 °C, 0 to 6 bar at 130 °C
Pressure Range bar g 0 to 16 bar at 25 °C, 0 to 6 bar at 130 °C
Pressure Range bar g 0 to 16 bar at 25 °C, 0 to 6 bar at 130 °C
Pressure Range bar g 0 to 4 bar
Pressure Range bar g 0 to 4 bar
Pressure Range bar g 0 to 4 bar
Number of Diaphragms
Number of Diaphragms 1
Number of Diaphragms 1
Number of Diaphragms 1
Number of Diaphragms 1
Number of Diaphragms 1
Number of Diaphragms 3
Number of Diaphragms 3
Number of Diaphragms 3
Number of Diaphragms 3
Number of Diaphragms 3
Number of Diaphragms 3
Autoclavable
Autoclavable Yes
Autoclavable Yes
Autoclavable Yes
Autoclavable Yes
Autoclavable Yes
Autoclavable No
Autoclavable No
Autoclavable No
Autoclavable No
Autoclavable No
Autoclavable No
Process Connection
Process Connection NPT 1" Thread
Process Connection NPT ¾" Thread
Process Connection NPT ¾" Thread
Process Connection NPT ¾" Thread
Process Connection NPT ¾" Thread
Process Connection PG13,5
Process Connection PG13,5
Process Connection PG13,5
Process Connection
Process Connection
Process Connection
ATEX Approval
ATEX Approval
ATEX Approval
ATEX Approval
ATEX Approval
ATEX Approval
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval
IECEx Approval
IECEx Approval
IECEx Approval
IECEx Approval
IECEx Approval
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
Shaft Diameter Below
Shaft Diameter Below
Shaft Diameter Below
Shaft Diameter Below
Shaft Diameter Below
Shaft Diameter Below
Shaft Diameter Below
Shaft Diameter Below
Shaft Diameter Below
Shaft Diameter Below 12 mm
Shaft Diameter Below 12 mm
Shaft Diameter Below 12 mm
Backed by world-class service and support.

For over 75 years, the Hamilton name has been recognized globally for its unwavering commitment to quality. That pledge extends to creating long-term customer partnerships. We're proud to offer in-depth training courses, on-site field support, custom product builds, and so much more.

Let's Talk

Connect with a Hamilton expert to discuss solutions for your workflow. We are here to enable your success.

Request Type: