PSD/6 Standard, PN: 63133-01 Specifications

Print
Accuracy ±1% @ 100% of stroke
Precision ≤ 0.05% @ 100% stroke
Fluid Path Borosilicate glass, PTFE, PFA, CTFE, ETFE, UHMW-PE, or ceramic
Weight 3.7 lbs (1.68 kg)
Power Requirements 24 VDC, 1.5A max
Syringe Drive Mechanism Stepper motor driven lead screw and optical encoder
Syringe Speed 2.0 seconds to 100 minutes per full stroke
Syringe Stroke Length 60 mm
Syringe Resolution Selectable 6,000 steps (standard) / 48,000 steps (high)
Syringe Drive Linear Force Capability 20 lbf (9.07 kgf)
Valve Drive Type Direct Drive DC stepper motor with 15 degree resolution and optical encoder.
Valve Drive Speed 250 ms per 120 degree rotation
Valve Drive Torque 25 (in oz)
Valve Fittings ¼-28
Communication Interface RS-232, RS-485, CAN
Communication Protocol Terminal and Standard
Baud Rate 9600 or 38400 (RS-232, RS-485) and 100,000 or 125,000 (CAN)
Data Bits 8
Parity None
Stop Bit 1, Half duplex
Daisy Chain Length Up to 16 syringe pumps or valve positioners
Operating Temp High 40 °C (105 °F)
Operating Temp Low 15 °C (60 °F)
Operating Humidity 20% to 95%, non-condensing
Storage Temp High 65 °C (150 °F)
Storage Temp Low -20 °C (-4 °F)
Storage Humidity 20% to 95%, non-condensing
RoHS 3 Compliant Yes
Baud Rates (available on requests) 19,200, 57,600, or 115,200 (RS-232, RS-485) 250,000, 500,000 or 1,000,000 (CAN)
Dimensions (D x H x W) 4.2 in x 8.99 in x 1.75 in
Configuration PSD/6 Standard

PSD/6 Standard, PN: 63133-01 Resources

Browse app notes, user guides, specification documents, and more in our Knowledge Center.

Browse app notes, user guides, specification documents, and more in our Knowledge Center.

Backed by world-class service and support.

For over 75 years, the Hamilton name has been recognized globally for its unwavering commitment to quality. That pledge extends to creating long-term customer partnerships. We're proud to offer in-depth training courses, on-site field support, custom product builds, and so much more.

Let's Talk

Connect with a Hamilton expert to discuss solutions for your workflow. We are here to enable your success.

Request Type: