Syringe Dimensions
700 Series Syringes
Volumes are based on 60 mm scale length except models 75 and 701 which are based on 54.1 mm scale length. O.D. dimensions are nominal and typical, I.D. dimensions are theoretical.
Model | Volume | Outer Diameter Nominal | Inner Diameter Theoretical Bore |
---|---|---|---|
75 | 5 | 6.6 mm (0.26 in) | 0.34 mm (0.014 in) |
701 | 10 | 6.6 mm (0.26 in) | 0.49 mm (0.019 in) |
702 | 25 | 7.7 mm (0.305 in) | 0.73 mm (0.029 in) |
705 | 50 | 7.7 mm (0.305 in) | 1.03 mm (0.041 in) |
710 | 100 | 7.7 mm (0.305 in) | 1.4 mm (0.061 in) |
725 | 250 | 7.7 mm (0.305 in) | 2.3 mm (0.091 in) |
750 | 500 | 7.7 mm (0.305 in) | 3.26 mm (0.135 in) |
7000 Series Syringes
Note: The plunger of a 7000 series syringe uses a tungsten wire that travels through the syringe to the tip of the needle. The seal is created by a PTFE ferrule within the knurled hub termination. The I.D. of the needle is honed to fit the tungsten wire. The displacement calculation is based on the O.D. of the plunger wire which is displayed as Theoretical Bore above. The O.D. is the outside diameter of the glass barrel.
Model | Volume | Outer Diameter Nominal | Inner Diameter Theoretical Bore |
---|---|---|---|
7000.5 (32 gauge) | 0.5 | 7.8 mm (0.308 in) | 0.104 mm (0.0041 in) |
7000.5 (25 gauge) | 0.5 | 7.8 mm (0.308 in) | 0.104 mm (0.0041 in) |
7001 (25 gauge) | 1 | 7.8 mm (0.308 in) | 0.145 mm (0.0057 in) |
7101 (22 gauge) | 1 | 7.8 mm (0.308 in) | 0.145 mm (0.0057 in) |
7002 (25 gauge) | 2 | 7.8 mm (0.308 in) | 0.206 mm (0.0081 in) |
7102 (23 gauge) | 2 | 7.8 mm (0.308 in) | 0.206 mm (0.0081 in) |
7105 (24 gauge) | 5 | 7.8 mm (0.308 in) | 0.325 mm (0.0128 in) |
1700 Series Syringes
Model | Volume | Outer Diameter Nominal | Inner Diameter Theoretical Bore |
---|---|---|---|
1701 | 10 | 6.6 mm (0.26 in) | 0.46mm (0.018 in) |
1702 | 25 | 7.7 mm (0.305 in) | 0.73 mm (0.029 in) |
1705 | 50 | 7.7 mm (0.305 in) | 1.03 mm (0.041 in) |
1710 | 100 | 7.7 mm (0.305 in) | 1.4 mm (0.057 in) |
1725 | 250 | 7.7 mm (0.305 in) | 2.3 mm (0.091 in) |
1750 | 500 | 7.7 mm (0.305 in) | 3.26 mm (0.128 in) |
1000 Series Syringes
Model | Volume | Outer Diameter Nominal | Inner Diameter Theoretical Bore |
---|---|---|---|
1001 | 1 | 9 mm (0.355 in) | 4.61 mm (0.181 in) |
1001.25 | 1.25 | 8.6 mm (0.329 in) | 5.15 mm (0.203 in) |
1002 (thin wall) |
2.5 | 9.7 mm (0.375 in) | 7.29 mm (0.287 in) |
1002 (thick wall) |
2.5 | 10.3 mm (0.407 in) | 7.29 mm (0.287 in) |
1005 | 5 | 13.5 mm (0.53 in) | 10.3 mm (0.406 in) |
1010 | 10 | 17.7 mm (0.695 in) | 14.57 mm (0.574 in) |
1025 | 25 | 27.1 mm (1.067 in) | 23.03 mm (0.907 in) |
1050 | 50 | 36.9 mm (1.452 in) | 32.54 mm (1.282 in) |
1100 | 100 | 36.9 mm (1.452 in) | 32.54 mm (1.282 in) |
Super Syringes
Model | Outer Diameter Nominal | Inner Diameter Theoretical Bore |
---|---|---|
S0500 | 75 mm (2.95 in) | 62 mm (2.44 in) |
S1000 | 100 mm (3.95 in) | 87 mm (3.44 in) |
S1500 | 101 mm (3.95 in) | 88 mm (3.44 in) |
S2000 | 102 mm (3.95 in) | 89 mm (3.44 in) |
Additional Resources for Hamilton Laboratory Products
See our comprehensive Needle Gauge Chart