Compare Products

ODO cap
ODO Cap H20 Optical Dissolved Oxygen Sensor Cap
ODO cap
Odo Cap H2
ODO cap
Odo Cap H2
ODO cap
Odo Cap H2
ODO Cap L0

The ODO Cap L0 is optimized for trace measurements ranging from 0.8 to 2,000 ppb and demonstrates stability against active chlorine and chlorine dioxide. It is designed as a replacement ODO Cap for the legacy VisiTrace DO Ex.

ODO Cap H20

The ODO Cap H20 is the standard option for water applications. As an Optical Dissolved Oxygen sensor cap, it is compatible with the VisiWater DO P Arc.

ODO Cap H0

The ODO Cap H0 is suitable for applications requiring a short response time and compatibility with most fermentation and culture media. It offers a basic design with standard chemical resistance and temperature stability. It is  compatible with the VisiFerm RS485 and the legacy VisiFerm DO sensors.

ODO Cap H2

The ODO Cap H2 is ideal for applications that need high chemical resistance and a hygienic design to simplify cleaning and minimize bubble formation. Suitable for chemically resistant applications where standard temperature stability is sufficient. Compatible with VisiFerm RS485, VisiFerm DO Arc, and VisiFerm DO ECS.

ODO Cap H3

 The ODO Cap H3 suitable  for most biopharmaceutical aqueous applications due to its better temperature stability, reduced calibration frequency, and longer cap life. With low drift and a short response time. As a default option for many applications, it is compatible with VisiFerm mA and VisiFerm RS485.

ODO Cap H4

The Optical Dissolved Oxygen Sensor Cap H4 is suitable for more chemical-intense industries. The convex design minimizes bubble accumulation and PTFE membrane increases chemical resistance. Compatible with VisiFerm mA and VisiFerm RS485-ECS.

ODO Cap L1

The ODO Cap L1 is optimized for trace measurements ranging from 0.8 to 2,000 ppb and shows stability against active chlorine and chlorine dioxide. Designed for a fast response time with measurements lower than 15 ppb, it serves as a replacement ODO Cap for VisiTrace mA and VisiTrace RS485.

ODO Cap H2 FFKM

The ODO Cap H2 FFKM has the same convex design and a PTFE membrane as the ODO Cap H2. Additionally, this cap comes with an FFKM seal, making it suitable for aggressive applications. Compatible with VisiFerm RS485, VisiFerm DO Arc, and VisiFerm DO ECS.

Wetted Parts Stainless Steel 1.4435
EPDM (Ethylene propylene elastomer)
VMQ (Silicone elastomer)
See compliance details in Material Specification document
Wetted Parts PA (Cycloaliphatic polyamide)
EPDM (Ethylene propylene elastomer)
VMQ (Silicone elastomer)
Wetted Parts Stainless Steel 1.4435
EPDM (Ethylene propylene elastomer)
VMQ (Silicone elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
PTFE (Polytetrafluoroethylene)
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
EPDM (Ethylene propylene elastomer)
VMQ (Silicone elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
PTFE (Polytetrafluoroethylene)
EPDM (Ethylene propylene elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
EPDM (Ethylene propylene elastomer)
VMQ (Silicone elastomer)
See compliance details in Material Specification document
Wetted Parts Stainless Steel 1.4435
PTFE (Polytetrafluoroethylene)
FFKM
See compliance details in Material Specification document
Sensor Compatibility VisiTrace DO Ex
Sensor Compatibility VisiWater DO P Arc
Sensor Compatibility VisiFerm RS485
VisiFerm DO Arc​
VisiFerm DO ECS
Sensor Compatibility VisiFerm RS485
VisiFerm DO Arc​
VisiFerm DO ECS
Sensor Compatibility VisiFerm RS485
VisiFerm mA
Sensor Compatibility VisiFerm RS485
VisiFerm mA
Sensor Compatibility VisiTrace mA
VisiTrace RS485
Sensor Compatibility VisiFerm RS485
VisiFerm DO Arc​
VisiFerm DO ECS
Surface Quality of Steel Ra < 0.4 µm (N5)
Surface Quality of Steel
Surface Quality of Steel Ra < 0.4 µm (N5)
Surface Quality of Steel Ra < 0.4 µm (N5)
Surface Quality of Steel Ra < 0.4 µm (N5)
Surface Quality of Steel Ra < 0.4 µm (N5)
Surface Quality of Steel Ra < 0.4 µm (N5)
Surface Quality of Steel Ra < 0.4 µm (N5)
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Serial Number Yes
Response Time t90% < 20 s in gas; < 90 s in water
Response Time t90% < 30 s at 25 °C
Response Time t98% < 30 s at 25 °C
Response Time t98% < 60 s at 25 °C
Response Time t98% < 30 s at 25 °C
Response Time t98% < 60 s at 25 °C
Response Time t90% < 20 s in gas; < 90 s in water
Response Time t98% < 60 s at 25 °C
Autoclavable Yes, max. Temperature 130 °C
Autoclavable No
Autoclavable Yes, max. Temperature 130 °C
Autoclavable Yes, max. Temperature 130 °C
Autoclavable Yes, max. Temperature 140 °C
Autoclavable Yes, max. Temperature 140 °C
Autoclavable Yes, max. Temperature 130 °C
Autoclavable Yes, max. Temperature 130 °C
Steam Sterilizable Yes, max. Temperature 140 °C
Steam Sterilizable
Steam Sterilizable Yes, max. Temperature 140 °C
Steam Sterilizable Yes, max. Temperature 140 °C
Steam Sterilizable Yes, max. Temperature 140 °C
Steam Sterilizable Yes, max. Temperature 140 °C
Steam Sterilizable Yes, max. Temperature 140 °C
Steam Sterilizable Yes, max. Temperature 140 °C
Operating Temperature Range -10 to 140 °C
Operating Temperature Range 0 to 60 °C
Operating Temperature Range -10 to 140 °C
Operating Temperature Range -10 to 140 °C
Operating Temperature Range -20 to 140 °C
Operating Temperature Range -20 to 140 °C
Operating Temperature Range -10 to 140 °C
Operating Temperature Range -10 to 140 °C
Backed by world-class service and support.

For over 75 years, the Hamilton name has been recognized globally for its unwavering commitment to quality. That pledge extends to creating long-term customer partnerships. We're proud to offer in-depth training courses, on-site field support, custom product builds, and so much more.

Let's Talk