Compare Products

Conductivity Sensor Conducell 4USF VP TC
Conductivity Sensor Conducell 4USF VP TC
Conducell 4USF VP TC 1.5 21

Engineered for demanding hygienic processes, this FDA-certified 4-pole conductivity sensor with a VP6 connector and Triclamp 1.5" process connection ensures reliable and linear measurements across a wide conductivity range, while its robust design withstands rigorous CIP, SIP, and autoclaving procedures, providing biopharmaceutical and similar users with a dependable solution for maintaining product quality and process control.

Conducell 4UHF VP TC 1.5 21

Engineered for demanding hygienic processes, this FDA-certified 4-pole conductivity sensor with a VP6 connector and Triclamp 1.5" process connection ensures reliable and linear measurements across a wide conductivity range, while its robust design withstands rigorous CIP, SIP, and autoclaving procedures, providing biopharmaceutical and similar users with a dependable solution for maintaining product quality and process control.

Electrical Connector VP6
Electrical Connector VP6
a-length 21 mm
a-length 21 mm
Measuring Range 1 µS/cm to 500 mS/cm
Measuring Range 1 µS/cm to 500 mS/cm
Cell Constant 0.36 /cm
Cell Constant 0.36 /cm
Temperature Sensor Pt1000
Temperature Sensor Pt1000
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Surface Quality of Steel Ra < 0.4 µm (N5, electropolished)
Process Connection Triclamp 1.5"
Process Connection Triclamp 1.5"
Serial Number Yes
Serial Number Yes
Certificate Yes, with nominal and actual cell constant
Certificate Yes, with nominal and actual cell constant
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
ATEX Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
IECEx Approval II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb; II 1/2 D ia IIIC T x °C Da/Db
Diameter 12 mm
Diameter 12 mm
Autoclavable Yes
Autoclavable Yes
Steam Sterilizable Yes
Steam Sterilizable Yes
CIP Yes
CIP Yes
Operating Temperature Range -20 to 150 °C
Operating Temperature Range -20 to 150 °C
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Pressure Range bar g 0 to 20 bar (135 °C), 0 to 10 bar (150 °C)
Electrode Material Stainless steel 1.4435
Electrode Material Hastelloy 2.4602
Backed by world-class service and support.