Microlab STAR Line
Experience Automation Your Way
The Microlab STAR Line automates liquid handling tasks from simple to complex with exceptional precision and flexibility so that you can increase throughput, reduce errors, and gain confidence in results.
Setting the Bar in Automated Liquid Handling Excellence
With thousands of installations in diverse laboratories across the globe, the Hamilton Microlab STAR Line is renowned for its engineering excellence and unlimited application potential.
Creating Value in Any Workflow
From simple nucleic acid extraction to complex cell-based assays requiring multiple on-deck devices, the Microlab STAR enhances efficiency and precision. The highly flexible design, along with a wide range of modules, carriers, and integrations, provide freedom to scale, change, and fully customize an automated solution to encompass workflow needs today and well into the future.
Smart Liquid Handling Starts Here
Compressed O-Ring Expansion II (CO-RE II) Technology creates a tight fit between the pipette channels and tips. This ensures precise tip alignment and highly accurate liquid handling.
Two sizes are available, each with up to sixteen 1 mL or up to eight 5 mL CO-RE pipetting channels. CO-RE 96 Probe and the 384 MultiProbe Head are also available for rapid pipetting into microplates.
VENUS Software offers intuitive drag-and-drop programming, including Power Steps for frequently used pipetting tasks.
Common applications Genomics, Nucleic Acid Extraction, Nucleic Acid Quantification & Normalization, PCR Set-Up, NGS Library Prep
Hamilton Technology Starts at the Channel
Liquid Handling Technology
-
Pipetting TechnologyFluid Motion Technology
More Workspace. More Performance. More Value.
Innovative drive system enhances the utilization of deck space, enabling researchers to automate more scientific experiments seamlessly within a single unit, ultimately saving valuable lab space.
-
Pipetting TechnologyDPS - Dynamic Positioning System
For Efficient Movements
DPS enables all channels to pipette simultaneously, even across non-uniform patterns. Unlike fixed channels with equidistant spreading, DPS offers efficient yet flexible liquid handling for cherry picking, non-uniform and variable volume samples, and complex pipetting workflows.
-
Pipetting TechnologyCO-RE II Tip/Tool Attachment
The Key to Liquid Handling Workflow Excellence
The new CO-RE II technology assures more precise tip alignment, minimizing the risk of collisions. Also, tip coupling is faster which boosts productivity. Besides tips, a wide range of Hamilton tools are applicable with CO-RE II.
-
Pipetting TechnologyAerosol-Free Tip Ejection
To Prevent Cross-Contamination
As part of CO-RE II technology’s functionality, pipette tips are gently ejected from each automated liquid handler pipetting channel. This prevents aerosol generation that may expose users to harmful biohazards or cross-contaminate samples and laboratory surfaces.
-
AccessoriesAutoload
For Convenient Identification
Uses a 1D barcode scanner to automatically identify and verify samples, carriers, and consumables such as tips, tubes, micro plates, and reagent troughs as they are placed onto the liquid handling deck. Optional 2D barcode reading is available, and results may be sent to any LIMS for documentation.
-
Transport SolutionsCO-RE Gripper
For Additional Movements
Further streamline automated workflows with CO-RE Grippers. These agile grippers transform Hamilton's precision pipette channels into on-deck labware transport solutions on Hamilton automated liquid handlers.
-
Transport SolutionsPlate Gripper
For Flexible Integration
Plate Grippers move labware to-and-from any position on the Hamilton automated liquid handling deck. For even greater hands-free efficiency and workflow integration, the Plate Grippers can transport plates to-and-from nearby off-deck devices (access location is platform-specific).
-
Pipetting TechnologyCapacitive Liquid Level Detection
For Accurate Pipetting
Channels are equipped with capacitance sensors that detect the liquid level through capacitive Liquid Level Detection (cLLD). Hamilton’s black conductive CO-RE tips facilitate capacitance sensing with the conductivity properties tailored for the capacitive liquids.
-
Pipetting TechnologyClot Detection
To Avoid Errors
Clot Detection pipetting channels are equipped with a pressure sensor that allows for pressure monitoring during aspiration and can detect blocked tips due to clots.
-
SoftwareGraphical User Interface
For Easy Operation
The intuitive graphical user interface (GUI) makes operation as simple as a smartphone app. Get started developing, editing, and running protocols without the need for automation or coding expertise.
With robust, repeatable, and hands-free performance, the Microlab STAR Line strengthens confidence in results while reducing the frequency of repeated work.
Preventative maintenance and expert Hamilton support keep your Microlab STAR running at peak condition during critical assays and over its lifespan.
Interchangeable tools, accessories, deck configurations, and intuitive software suit a wide range of dynamic workflow needs.
Explore the Microlab STAR
Pipetting Configurations
Deck Space and Integration
Status Light Bar
VENUS Software
CO-RE Channel Enhancements
Optional Process Integrity Tools
Microlab STAR Specifications
Microlab STAR Specifications
PrintSystem Dimensions
- Height
- 90.3 cm (2 ft, 11.55 in)
- Width
- 1.66 m (5 ft, 5.51 in)
- Depth
- 78.1 cm to 1.01 m (2 ft, 6.75 in to 3 ft, 3.8 in)
General Specifications
- Weight
- 145 kg
Transport Tools
- CO-RE Gripper
- Optional
- Internal Plate Gripper (IPG)
- Optional
Platform/Accessories
- IVDR Compliant
- No
- Capacity (ANSI/SLAS Positions)
- 55
- Device Integration
- 180° (Left and Right)
Sample Loading and Tracking Options
- Sample Loading
- Automatic, Continuous
- Manual Load
- Standard
- Autoload Barcode Scanner (1D)
- Optional
- Autoload Barcode Scanner (2D)
- Optional
Pipetting Options
- 1 mL Channels
- Up To 16
- 5 mL Channels
- Up To 8
- Fluid Motion X1 Channels
- Up To 16
- MagPip Channels
- n/a
- Multi-Probe Head Option
- 96 and/or 384
- Pipetting Range 1
- 1 µL - 5000 µL
Microlab STAR IVD Specifications
PrintSystem Dimensions
- Height
- 90.3 cm (2 ft, 11.55 in)
- Width
- 1.66 m (5 ft, 5.51 in)
- Depth
- 78.1 cm to 1.01 m (2 ft, 6.75 in to 3 ft, 3.8 in)
General Specifications
- Weight
- 145 kg
Transport Tools
- CO-RE Gripper
- Optional
- Internal Plate Gripper (IPG)
- Optional
Platform/Accessories
- IVDR Compliant
- Yes, 2017/746/EU (IVDR)
- Capacity (ANSI/SLAS Positions)
- 55
- Device Integration
- n/a
Sample Loading and Tracking Options
- Manual Load
- No
- Autoload Barcode Scanner (1D)
- No
- Autoload Barcode Scanner (2D)
- Standard
Pipetting Options
- 1 mL Channels
- Up To 16
- 5 mL Channels
- Up To 8
- Fluid Motion X1 Channels
- n/a
- MagPip Channels
- n/a
- Multi-Probe Head Option
- n/a
- Pipetting Range 1
- 1 µL - 5000 µL
Microlab STARlet Specifications
PrintSystem Dimensions
- Height
- 90.3 cm (2 ft, 11.55 in)
- Width
- 1.12 m (3 ft, 8.25 in)
- Depth
- 78.1 cm to 1.01 m (2 ft, 6.75 in to 3 ft, 3.8 in)
General Specifications
- Weight
- 135 kg
Transport Tools
- CO-RE Gripper
- Optional
- Internal Swivel Arm Plate Handler (iSWAP)
- Optional
Platform/Accessories
- IVDR Compliant
- No
- Capacity (ANSI/SLAS Positions)
- 25
30 (with FM channels)
- Device Integration
- 180° (Left and Right)
Sample Loading and Tracking Options
- Sample Loading
- Automatic, Continuous
- Manual Load
- Standard
- Autoload Barcode Scanner (1D)
- Optional
- Autoload Barcode Scanner (2D)
- Optional
Pipetting Options
- 1 mL Channels
- Up To 16
- Fluid Motion X1 Channels
- Up To 16
- MagPip Channels
- n/a
- Multi-Probe Head Option
- 96
- Pipetting Range 1
- 1 µL - 5000 µL
1 Depending on Configuration
Support your entire workflow with Hamilton's integrated products.
Sample Storage Integration
Link your Hamilton automated liquid handling system to a sample storage system such as our Verso Q-Series to create a fully automated processing center.
Extend with Integrated Devices
From heating to shaking, to cooling and much more. The expandable modules create added value for every workflow in every laboratory, and also maximize walk-away time.
Microlab STAR Resources
Browse app notes, user guides, specification documents, and more in our Knowledge Center.
Browse app notes, user guides, specification documents, and more in our Knowledge Center.
Browse app notes, user guides, specification documents, and more in our Knowledge Center.
Browse app notes, user guides, specification documents, and more in our Knowledge Center.
Browse app notes, user guides, specification documents, and more in our Knowledge Center.
Trust in Hamilton’s Field Service Engineers for high-quality automated liquid handler installation, preventative maintenance, and field repairs.
Maximize your Hamilton Automated Liquid Handling System’s performance with our three pillars of pipetting excellence: Verify, Check, and Monitor for unmatched precision.
Hamilton’s Advanced Product Engineering group delivers custom, high-performance automation systems with rapid deployment and minimal maintenance.
Hamilton’s Field Service Engineers adapt your Hamilton automated liquid handler to your changing needs so you can achieve new goals.
From our Field Service Engineers to our compliance with regulatory standards, you can expect high quality from Hamilton.
For over 75 years, the Hamilton name has been recognized globally for its unwavering commitment to quality. That pledge extends to creating long-term customer partnerships. We're proud to offer in-depth training courses, on-site field support, custom product builds, and so much more.
Connect with a Hamilton expert to discuss solutions for your workflow. We are here to enable your success.
Request Type: