VisiFerm mA 160 H3
The VisiFerm mA 160 H3 is the next generation optical dissolved oxygen (DO) sensor for use in explosive environment. Designed especially for production environments, the VisiFerm mA is a 2-wire sensor with 4-20 mA standard or digital HART signal output, and ATEX, UKEx & IECEx approval. The VisiFerm optical technology improves the measuring performance and simplifies maintenance. Improvements compared to conventional electrochemical (amperometric) sensors include flow independence, rapid startup with no polarization time, and no nA noise. It requires less maintenance than an amperometric oxygen sensor as it does not have a mechanically sensitive membrane or a corrosive electrolyte. The VisiFerm mA mitigates the negative effects of aging, temperature, and photobleaching in order to reduce the frequency of calibration and deviation reports.
Found in these product categories:
Part/REF # 10070760-1211-
(In Stock)(In Stock)Stock status is updated daily. For real-time status, please contact us.
Specifications
Sensor Family |
Sensor Family
VisiFerm mA
|
---|---|
a-length |
a-length
160 mm
|
Electrical Connector |
Electrical Connector
M12
|
Measurement Principle |
Measurement Principle
Oxygen dependent luminescence quenching, temperature compensation
|
Measuring Range |
Measuring Range
4 ppb to 25 ppm (DO) 0 to 62.85 %-vol or 0 to 300 %-sat
|
Accuracy at 25 °C |
Accuracy at 25 °C
1 ± 0.05 %-vol: 21 ± 0.2 %-vol; 50 ± 0.5 %-vol
|
Drift at Room Temperature |
Drift at Room Temperature
< 1 % per week
|
Additional specifications
Sensor Cap |
Sensor Cap
ODO Cap H3
|
---|---|
Electrolyte |
Electrolyte
None
|
Oxygen Consumption |
Oxygen Consumption
None
|
Temperature Sensor |
Temperature Sensor
NTC 22 kOhm
|
Configurable Values |
Configurable Values
DO: mbar; %-sat; %-vol; µg/l; mg/l; ppb/ppm (gas); ppb/ppm (dissolved oxygen); Temperature: °C
|
Diameter |
Diameter
12 mm
|
Process Connection |
Process Connection
PG13,5
|
Wetted Parts |
Wetted Parts
Stainless Steel 1.4435
EPDM (Ethylene propylene elastomer) VMQ (Silicone elastomer) See compliance details in Material Specification document |
Surface Quality of Steel |
Surface Quality of Steel
Ra < 0.4 µm (N5)
|
4 to 20 mA Current Range |
4 to 20 mA Current Range
3.5 to 22 mA
|
Analog Interface 1 |
Analog Interface 1
Two wire sink 4 to 20 mA for DO, programmable
|
4 to 20 mA Accuracy |
4 to 20 mA Accuracy
< 0.3 % current value + 0.05 mA
|
Transmitting Power |
Transmitting Power
Max. 4 dBm
|
Digital Interface |
Digital Interface
Bluetooth 5.0
HART Version 7.0 |
Operating Voltage |
Operating Voltage
18 to 30 VDC
|
Serial Number |
Serial Number
Yes
|
Response Time |
Response Time
t98% < 30 s at 25 °C
|
Certificate |
Certificate
Yes, with measured current in air
|
ATEX Approval |
ATEX Approval
ll 1 G Ex ia llC T3/T4/T5/T6 Ga; II 1 D Ex ia IIIC T135°C Da
|
IECEx Approval |
IECEx Approval
ll 1 G Ex ia llC T3/T4/T5/T6 Ga; II 1 D Ex ia IIIC T135°C Da
|
Autoclavable |
Autoclavable
Yes
|
CIP |
CIP
Yes
|
Steam Sterilizable |
Steam Sterilizable
Yes, max. Temperature 140 °C
|
Operating Temperature Range |
Operating Temperature Range
-20 to 140 °C; the sensor provides no DO reading above 85 °C
|
Pressure Range bar g |
Pressure Range bar g
-1 to 12 bar
|
Protection Rating |
Protection Rating
IP 68
|
Required Flow |
Required Flow
None
|
Resources
Documents
-
Brochure
-
Catalogs
-
Certificates
- ATEX Certificate TÜV 18 ATEX 8236 X - VisiFerm mA DO / VisiTrace mA DO Sensors (PDF)
- BSE / TSE / Jatropha Statement (PDF)
- Certificate - China RoHS Hazardous Substances in Parts (PDF)
- Certificates for Raw Material according the EN 10204-3.1.B
- Declaration of Quality for Calibration Solutions
- EU Declaration of Conformity - VisiFerm mA and VisiTrace mA Sensors (ATEX) (PDF)
- IEXEx Conformity - VisiFerm mA and VisiTrace mA Sensors (PDF)
- Wireless Certificate - VisiFerm mA & VisiTrace mA (Canada) (PDF)
- Wireless Certificate - VisiFerm mA & VisiTrace mA (Japan) (PDF)
- Wireless Certificate - VisiFerm mA & VisiTrace mA (USA) (PDF)
- Wireless Certificate - VisiFerm mA (China) (PDF)
- Wireless Certificate - VisiFerm mA (India) (PDF)
-
Material Specifications
-
Technical Drawings
-
Technical Manuals
Related Content
- Are there any backwards compatibility limitations with VisiFerm RS485? FAQ
- What are the improved calibration features for the VisiFerm RS485? FAQ
- If I use H0 and H2 caps, why should I upgrade to the VisiFerm RS485? FAQ
- Do I need to use the H3/H4 caps to experience the full benefits of the VisiFerm RS485? FAQ
- Will the Arc Wi 1G or 2G Adapter need a firmware update for compatibility with the VisiFerm RS485? FAQ
We're Ready to Help
Hamilton's sales, customer service, and technical support staff are available for questions and additional information about all products and services.
Contact Us