Polarographic Dissolved Oxygen Sensors
Hamilton ist seit vielen Jahren führend in der Messung von Gelöstsauerstoff. Die Produktlinie der polarographischen (amperometrischen) DO-Sensoren umfasst die hygienischen 12mm-Sensordesigns, die für Anwendungen in den Bereichen Biopharmazie, Lebensmittel, Getränke und Wasseraufbereitung geeignet sind.
OxyFerm
OxyGold G
Oxysens
Was macht die polarographischen Sensoren von Hamilton anders?
-
Simple to service
The plug-in cathode kit makes servicing the sensor quick and easy.
-
Options
Hamilton offers specialized polarographic sensors suitable for trace oxygen measurement, high carbon dioxide environments, and sanitary applications.
-
Approvals
Most Hamilton polarographic dissolved oxygen sensors have a variety of agency approvals making them suitable for multiple industries.
Technische Merkmale
OxyFerm | OxyGold G | Oxysens | |
---|---|---|---|
Messbereich | 10 ppb - 40 ppm (DO) | 1 ppb - 40 ppm (DO) | 40 ppb - 40 ppm (DO) |
Reaktionszeit t98% | < 60 s at 25 °C von Luft zu Stickstoff | < 60 s at 25 °C von Luft zu Stickstoff | < 60 s at 25 °C von Luft zu Stickstoff |
Druckbereich | 0 – 4 bar | 0 – 12 bar | 0 – 4 bar |
Hygieneaspekte | Autoklavierbar, CIP, SIP | Autoklavierbar, CIP, SIP | -- |
Electrolyte | Oxylyte | Oxylyte G | Oxylyte |
Oberflächenqualität | Ra < 0,4 μm (N5) | Ra < 0,4 μm (N5) | Ra < 0,8 µm (N6) |
Strömung in der Luft | 40 - 80 nA | 180 - 500 nA | 40 - 80 nA |
Material | Edelstahl 1.4435 | Edelstahl 1.4435 | Edelstahl 1.4435 |
Polarisationsspannung | -670 mV | -670 mV | -670 mV |
Dichtungsring | EPDM | EPDM | EPDM |
Downloads & FAQ
-
Catalog - Process Analytics
Download the Process Analytics sensor catalog to learn about the complete offering of Hamilton process sensors and accessories. -
Brochure - BioPharma
Innovative solutions for process analytics in biotechnological and pharmaceutical industries. -
Brochure - Brewery
Learn about our control and analytical solutions that are essential to the brewing process.
-
Does salinity impact my DO measurement?
Yes, salinity of a solution generally has an inverse relationship to the dissolved oxygen content within the solution. Arc sensors can have the salinity value of the liquid added in to correct the measurement by using ArcAir. -
Does temperature impact my oxygen measurement?
Yes, in a closed system, gas phase temperature is directly proportional to pressure and therefore measured oxygen content. In solution, temperature is inversely proportional to dissolved oxygen content. -
Does carbon dioxide sparging impact my DO measurement?
CO2 sparging will not impact the DO measurement using an optical DO sensor. CO2 can impact traditional polarographic DO sensors over time thus more frequent electrolyte replacement may be needed.