The VisiFerm DO Arc 120 H0 is designed to meet the demanding needs of hygienic applications in the biotechnology, bio pharmaceutical, and food and beverage industry. The VisiFerm DO Arc optical dissolved oxygen sensor offers a simple way to upgrade from traditional polarographic sensors. The sensor measurement principle offers increased accuracy and reduced maintenance while the output provides both 4 - 20mA and Modbus digital outputs.
The next generation VisiFerm drastically reduces calibration frequency and has a higher robustness. Learn more about the new sensors:
-
(In Stock)(In Stock)Stock status is updated daily. For real-time status, please contact us.
Specifications
a-length |
a-length
120 mm
|
---|---|
Electrical Connector |
Electrical Connector
VP8
|
Sensor Output |
Sensor Output
Traditional: mA
|
Measurement Principle |
Measurement Principle
Oxygen dependent luminescence quenching, temperature compensation
|
Measuring Range |
Measuring Range
4 ppb to 25 ppm (DO) 0 to 62.85 %-vol or 0 to 300 %-sat
|
Accuracy at 25 °C |
Accuracy at 25 °C
1 ± 0.05 %-vol: 21 ± 0.2 %-vol; 50 ± 0.5 %-vol
|
Drift at Room Temperature |
Drift at Room Temperature
< 1 % per week
|
Additional specifications
Sensor Cap |
Sensor Cap
ODO Cap H0
|
---|---|
Electrolyte |
Electrolyte
None
|
Oxygen Consumption |
Oxygen Consumption
None
|
Temperature Sensor |
Temperature Sensor
NTC 22 kOhm
|
Configurable Values |
Configurable Values
DO: mbar; %-sat; %-vol; µg/l; mg/l; ppb/ppm (dissolved oxygen); Temperature: °C, °F, K
|
Diameter |
Diameter
12 mm
|
Process Connection |
Process Connection
PG13,5
|
Wetted Parts |
Wetted Parts
Stainless Steel 1.4435
EPDM (Ethylene propylene elastomer) Silicone - FDA 21 CFR 177.2600 VMQ (Silicone elastomer) See compliance details in Material Specification document |
Surface Quality of Steel |
Surface Quality of Steel
Ra < 0.4 µm (N5)
|
Analog Interface 1 |
Analog Interface 1
4 to 20 mA for DO, programmable, galvanically not isolated; pulse width modulation 5 kHz
|
Digital Interface |
Digital Interface
RS485 Modbus (max. 31 addresses)
|
Baud Rate |
Baud Rate
4800, 9600, 19200, 38400, 57600,115200 Bd
|
Operating Voltage |
Operating Voltage
7 to 30 VDC max. 1 W
|
Serial Number |
Serial Number
Yes
|
Response Time |
Response Time
t98% < 30 s at 25 °C
|
Certificate |
Certificate
Yes, with parameter settings and materials used
|
ATEX Approval |
ATEX Approval
No
|
IECEx Approval |
IECEx Approval
No
|
Autoclavable |
Autoclavable
Yes, max. Temperature 130 °C
|
CIP |
CIP
Yes
|
Steam Sterilizable |
Steam Sterilizable
Yes, max. Temperature 140 °C
|
Operating Temperature Range |
Operating Temperature Range
-10 to 140 °C; the sensor provides no DO reading above 85 °C
|
Pressure Range bar g |
Pressure Range bar g
-1 to 12 bar
|
Required Flow |
Required Flow
None
|