Conducell-PO SU

Specification Sheet (Part/REF # 10187044)

Incyte P SU - conductivity probe

Hamilton’s Conducell-PO SU is a sensor element for biopharma processes. The Conducell-PO SU is designed to be pre-installed as an integral part of a single-use bag. It is optimized for welding to various bag films. It connects to the Arc Module Cond SU for reliable measurement in single-use applications.

Product Specifications

Measurement Principle
Measurement Principle
4 Pole Contacting
Measuring Range
Measuring Range
100 µS/cm to 300 mS/cm
Accuracy at 25 °C
Accuracy at 25 °C
± 5 % at 100 µS/cm to 100 mS/cm
± 8 % at 100 mS/cm to 200 mS/cm
± 10 % at 200 mS/cm to 300 mS/cm
Drift at 25 °C
Drift at 25 °C
No observable drift
Wet-in Time
Wet-in Time
< 30 min (after dry storage)
Response Time at 25 °C
Response Time at 25 °C
t98% < 30 s (1.413 to 300 mS/cm)
Shelf Life
Shelf Life
24 months before irradiation
37 months after irradiation
Patch type
Patch type
Overmold (See drawing)
Sensor Output
Sensor Output
Electrical resistivity
NTC 22 kOhm (temperature resistor)
Wetted Parts
Wetted Parts
Platinum
Glass / Ceramic
HDPE (High Density Polyethylene)
TPE-O (LDPE) (Thermoplastic Elastomer Olefinic Base)
See compliance details in Material Specification document
Burst Pressure
Burst Pressure
Up to 10 barg
Operating Temperature Range
Operating Temperature Range
4 to 50 °C
Storage Temperature Range
Storage Temperature Range
4 to 40 °C in non-condensing environment (<85% r. H.)
Transport Temperature Range
Transport Temperature Range
-30 to 60 °C (according to ASTM D4169-13)
Sterilization
Sterilization
Gamma irradiation compatible (up to 50 kGy)
X-Ray irradiation compatible (up to 50 kGy)
Not validated for autoclavation, Sterilization In Place (SIP), nor Cleaning In Place (CIP)
Chemical Resistance
Chemical Resistance
See Chemical Resistance Guide
Spec. Version C