VisiFerm DO SU Arc 225 C
The VisiFerm DO SU ARC 225 C for single-use applications works with Hamilton single-use ODO Cap . The VisiFerm DO SU ARC 225 C is reusable and can be mounted directly into the ODO Cap within the bag or SU bioreactor.
Found in these product categories:
Part/REF # 10087920
-
(In Stock)(In Stock)Stock status is updated daily. For real-time status, please contact us.
Specifications
Sensor Family |
Sensor Family
Visiferm SU
|
---|---|
a-length |
a-length
215 mm
|
Electrical Connector |
Electrical Connector
VP8
|
Sensor Output |
Sensor Output
Arc: Modbus, 4 to 20 mA
|
Measurement Principle |
Measurement Principle
Oxygen dependent luminescence quenching, temperature compensation
|
Measuring Range |
Measuring Range
4 ppb to 25 ppm (DO)
0 to 62.85 %-vol 0 to 300 %-sat |
Accuracy at 25 °C |
Accuracy at 25 °C
± 1.0 %-sat (at 20 %-sat), only in combination with the gamma irradiated Hamilton single-use ODO Cap and with product calibration
± 1.0 %-sat (at 100 %-sat), only in combination with the gamma irradiated Hamilton single-use ODO Cap and with product calibration ± 2.5 %-sat (at 200 %-sat), only in combination with the gamma irradiated Hamilton single-use ODO Cap and with product calibration |
Additional specifications
Drift at Room Temperature |
Drift at Room Temperature
< 1 % per week (of measurement value)
|
---|---|
Electrolyte |
Electrolyte
None
|
Oxygen Consumption |
Oxygen Consumption
None
|
Temperature Sensor |
Temperature Sensor
NTC 22 kOhm
|
Configurable Values |
Configurable Values
DO: mbar; %-sat; %-vol; µg/l; mg/l; ppb/ppm (gas); ppb/ppm (dissolved oxygen); Temperature: °C
|
Diameter |
Diameter
12 mm
|
Analog Interface 1 |
Analog Interface 1
4 to 20 mA for DO, programmable, galvanically not isolated; pulse width modulation 5 kHz
|
Digital Interface |
Digital Interface
RS485 Modbus (max. 31 addresses)
|
Baud Rate |
Baud Rate
4800, 9600, 19200, 38400, 57600,115200 Bd
|
Operating Voltage |
Operating Voltage
7 to 30 VDC max. 1 W
|
Serial Number |
Serial Number
Yes
|
Response Time |
Response Time
t98% < 30 s at 25 °C
|
Certificate |
Certificate
Yes, with parameter settings and materials used
|
ATEX Approval |
ATEX Approval
No
|
Autoclavable |
Autoclavable
No
|
CIP |
CIP
No
|
Steam Sterilizable |
Steam Sterilizable
No
|
Gamma Irradiatable |
Gamma Irradiatable
No
|
Operating Temperature Range |
Operating Temperature Range
0 to 60 °C
|
Required Flow |
Required Flow
None
|
Resources
Documents
-
Brochure
-
Catalogs
-
Certificates
-
Flyers
-
Software Downloads
-
Technical Drawings
-
Technical Manuals
-
Technical Note

We're Ready to Help
Hamilton's sales, customer service, and technical support staff are available for questions and additional information about all products and services.
Contact Us