Hamilton’s PRP-C18 is the First Choice for Oligonucleotide Purifications

Synthetic oligonucleotide (oligo) purifications are demanding applications that are typically performed at elevated (> 60°C) temperatures in order to facilitate resolution between the target oligo and closely-related failure sequences. Traditional silica-based C18 (ODS) columns have diminished lifetime at elevated temperatures, however, polymeric polystyrene-divinylbenzene (PS-DVB) columns are routinely used to purify synthetic oligonucleotides due to their superior temperature (> 100°C) and pH (1–14) stability.

Oligonucleotide HPLC

Why PRP-C18?

The Hamilton PRP-C18 is a next generation polymeric column based on porous C18-functionalized PS-DVB that exhibits excellent chemical and thermal stability. Unlike other polymer columns, the octadecylated surface modification imparts superior mass transfer kinetics for high efficiency separations and excellent mechanical stability.

PRP-C18 Benefits:

  • Superior resolution for purer oligos
  • Extended column lifetime for increased productivity
  • High loading capacity for time and cost savings

Resilient Design Ensures More Oligo Manufacturing

The flexibility to employ elevated temperatures (up to 100°C) and alkaline pH are important tools in oligonucleotide purifications. Traditional silica-based supports break down at elevated temperatures, leading to stationary phase bleeding and diminished column lifetimes. The PRP-C18 does not dissolve, phase-strip, or bleed even under the most extreme operating conditions, unlocking the power of superior resolution between long oligos and their failure sequences. Because the PRP-C18 stationary phase is devoid of silanols found in silica-C18 columns, peak tailing, poor recovery, and carry-over problems are completely eliminated, offering significant value.

Full pH Range Compatibility

Unlike traditional silica-based C18 columns, the PRP-C18 is stable over a pH range of 1–14. The flexibility to employ alkaline mobile phase (pH 12) is useful for separating problematic oligos that form secondary structures or aggregates.

High pH Column Lifetime Comparison

oligonucleotide purification chart

Forced degradation study comparing longevity of traditional ODS and Hamilton PRP-C18 columns under elevated temperature (60°C) and alkaline pH (50 mM phosphate, pH 12) conditions.

Oligonucleotide Purification Download Document

Want to take this page’s content to go?
Download this page as a PDF.

DOWNLOAD WEB PAGE AS A PDF

Higher Oligo Yield with Extended Loading Capacity

The high loading capacity and greater resolving power of the PRP-C18 makes it possible to achieve baseline resolution between failure sequences and the target 21mer, which is collected in a single fraction. Subsequent analytical chromatography of the purified fraction indicate oligo purification to > 99% (UV).

2 mg prep load
10 x 100 mm, 5 μm PRP-C18

oligonucleotide purification graph

Confirmed > 99% purity
4.1 x 50 mm, PRP-C18

oligonucleotide purification graph with confirmed >99% purity

High Purity Oligos with High-Resolution Separations

The performance of the PRP-C18 and two leading oligo columns at increasing temperatures is shown in the graphs below. The PRP-C18 shows the best resolution of poly(dC) 12–18 ladder at all temperatures.

Waters XTerra™
2.1 x 100 mm, 5 μm

Hamilton PRP-C18
2.1 x 150 mm, 5 μm



Ordering Information

PRP-C18 Columns

Hardware
(Particle Size)
Stainless Steel
(5 μm)
PEEK
(5 μm)
Stainless Steel
(12–20 μm)
2.1 x 50 mm 79672 79679
2.1 x 150 mm 79673 79680
2.1 x 250 mm 79674 79681
4.6 x 50 mm 79675 79682
4.6 x 150 mm 79676 79683
4.6 x 250 mm 79677 79684
21.2 x 250 mm 79678

* Not Seeing the Hardware Dimensions you need? We offer many custom sizes to suit your needs.

Click below to see what other column sizes we can offer.

PRP-C18 Guard Columns Ordering Information

Part Number Description
79685 Analytical Guard Column Starter Kit (1 holder, 2 cartridges), Stainless Steel
79686 Analytical Guard Column Replacement Cartridges (5/pk), Stainless Steel
79687 Analytical Guard Column Starter Kit (1 holder, 2 cartridges), PEEK
79688 Analytical Guard Column Replacement Cartridges (5/pk), PEEK
79689 Semi-prep/Preparative Guard Column Starter Kit (1 holder, 1 cartridge), Stainless Steel
79690 Semi-prep/Preparative Guard Column Replacement Kit (2/pk), Stainless Steel

Other Packing Materials for Oligo Purification

Syringe Custom Built

Work with R&D engineers to customize Hamilton parts

Hamilton's "Custom Built" program puts you directly in contact with a Hamilton R&D Engineer to discuss your application and product needs. The engineer will point you to a standard solution or propose a customized solution to meet your needs.

Talk to an engineer