Demo Methods Download


Demo Methods DownloadAll the Demo Methods described in the VENUS one Programmer's Manual can be downloaded from this section. This offers you the chance to, in addition to the manual, directly see what has been programmed and how it works in simulation mode or on your Hamilton instrument.

The number in brackets gives you the chapter of Programmer's Manual, where the specific method is described.

IMPORTANT: Depending on the settings during the software installation, not all necessary labware may be activated. To see how to activate needed labware, click here.

Each demo method zip file contains a list showing the used labware in this method.

UV Decontamination V1.3.0 validated, zip
SW VENUS 4.4IVD/one/two: This Method will move the arm mounted with a UV Lamp from position A to B for a defined time after a defined delay.

NIMBUS ARTEL MVS Pipetting Performance Method, zip
SW VENUS one: This method supports NIMBUS pipetting of ARTEL dyes to specified microtiter plate for pipetting performance evaluation.The library that is in this directory must be installed BEFORE method will run (you need to change the install file extension to .msi).

STAR ARTEL MVS Pipetting Performance Method, zip
SW VENUS one: This method supports STAR pipetting of ARTEL dyes to specified microtiter plate for pipetting performance evaluation.The library that is in this directory must be installed BEFORE method will run (you need to change the install file extension to .msi).

Nimbus Barcode Example, pkg
This NIMBUS method shows how to read a 1D barcode on MTPs, DWPs and NTRs using the NIMBUS labware gripper.

LLD Check, zip
This method shows how to speed up the use of the cLLD detection with 1000ul Channels (11.10).

Mix Samples And Buffer, zip
This method describes using the action editor with 1000ul channels (12.2).

OnePlateToPlatePipette, zip
This methods describes how to copy a plate using SMART Steps with 1000ul Channels (12.3).

One Plate To Plate Easy Steps, zip
This methods describes how to copy a plate using SINGLE and Easy Steps with 1000ul Channels (12.4).

TubesToPlatePipette, zip
This methods copies tubes to plates using SMART Steps with 1000 ul Channels (12.5).

HitPicking, zip
This method describes how to programm a method with results from a excelfile with 1000ul Channels (12.6).

Demo96To384, zip
This method copies four 96 well plates into a 384 well plate with CO-RE 96 Probe Head (12.7).

Demo384Serial Dilution, zip
This method supports the use of the CO-RE 384 STP with a serial Dilution (12.8).

Demo Submethod, zip
This method describes how to build sub-methods and how to invoke a sub-method library for a particular function with 1000ul Channels (12.8).

DemoiSwap, zip
This method describes the use of the iSWAP with 1000ul Channels (15.3).

TubeGripper, zip
This method supports the use of the Tube Gripper with 1000ul Channels (16.1).

DemoCo-ReGrip, zip
This method describes the use of the CO-RE Gripper plate handler and the use of arrays with 1000ul Channels (17.2).

DemoBarcodeReadingWithCoRe, zip
This method shows how to read a platebarcode with using the CO-RE Gripper with 1000ul Channels (17.5.2).

DemoWashStation, zip
This method supports the use of the CR Needle Wash Station for 1000ul Channels (18.3).

Demo96Wash Station, zip
This method supports the use of the 96 Wash Station for disposable tips with 96 CORE Head (20.2).

Demo96-384Wash Station, zip
This method supports the use of the 96-384Wash Station for disposable tips with 96 or 384 CORE Head (21.3).

DemoTCC, zip
This method supports the use of the TCC with 1000ul Channels (22.2).

DemoBVS, zip
This method describes the use of the BVS Vacuum System with 1000ul Channels (23.3).