Specialty Needles

Over the years Hamilton Company has created a number of custom syringes and needles. This category contains all of the application specific needles for Neuroscience, OEM Integration, DNA Gel Loading, and more.

Glass Micro Pipettes


There are many applications where using a glass needle is superior to using a metal needle. Glass needles are widely used in Neuroscience applications because the point can be pulled to an incredibly small diameter and maintain the rigidity to penetrate tissue. Additionally since the dispense hole exits from the very tip of the needle the wound track can be minimized.
Stainless Steel Tubing


Some custom applications require just the cannula from a standard needle. This category of needles comes without a hub so they cannot be connected to a Hamilton syringe. The length of the tubing can be specified at the time of order.
Stainless Steel Tubing (with Point Style)


Some custom applications require just the cannula from a standard needle. This category of needles comes without a hub so they cannot be connected to a Hamilton syringe. The point style and length of the tubing can be specified at the time of order.
Thin Layer Chromatography Needles


The thin layer chromatography (TLC) needles are coated with PTFE 3/4" up the needle from the tip. The coating reduces the surface tension between the needle and the liquid making it ideal for reproducible sample spotting. These needles are available as a removable needle (RN) small or large hub and will connect to the appropriate RN syringes.
Valve Port - Hat Type Needles


Hat type needles are designed to be connected directly to a flat bottom valve port. Use the Needle Bushing part number 35056 to connect the needle directly to any 1/4-28 Hamilton valve.
Needles - Multichannel Gel Loading Syringe


These are replacement needles for the fixed width Gel Loading Syringe. The needles are available in 0.2, 0.3, and 0.4 mm outer diameters. The 0.2 and 0.3 mm needles are jacketed with a thicker gauge needle so only a short distance of the fine gauge needle is exposed. This added protection minimizes damage to the fine gauge needle.
Needles - Adjustable Multichannel Gel Loading Syringe


These are replacement needles for the adjustable width Gel Loading Syringe. The needles are available in 0.2 and 0.3 mm outer diameters. The needles are jacketed with a thicker gauge needle so only a short distance of the fine gauge needle is exposed. This added protection minimizes damage to the fine gauge needle.
Roll the cursor over the menu headers below to see the available selections. Filter by one or more items in any order to narrow your search down to a single part number in this category. Reset a filter by clicking the red X that appears next to a filtered item. For more detail on any menu item, click the question mark on the right-hand side of the menu bar.

          Part Number
          Description
          Unit Price
          Quantity

          Hub

          Metal hub (nickel plated brass) needles can be used with TLL syringes and LT or TLL connectors. The needless are 304 stainless steel (sst.). Standard needle length is 2" / 51 mm. Metal hub (N) needles are available in convenient six packs. Custom needle lengths and point styles are available.

          Kel-F hub (KF) needles can be used with Luer Tip (LT) and PTFE Luer Lock (TLL) syringes and connectors. Standard needle length is 2" / 51 mm. Kel-F hub (KF) needles are available in convenient six packs. Custom lengths and point styles are available.

          Gauge

          When selecting a needle gauge it is important to keep in mind the volume of the syringe and the dead volume of the needle. For example, it will be very difficult to prime a 10 µL syringe if the dead volume in the needle is greater than 10 µL. Refer to the gauge index to choose a needle gauge with an appropriate µL/inch before selecting a needle. Select the minimum length that allows you to carry out your application comfortably.

          Note: The ‘s’ on a 22s needle represents a smaller I.D. (inner diameter) for the needle and a thicker needle wall for better durability. For example, a 26 gauge needle has an O.D. (outer diameter) of 0.46 mm and an I.D. of 0.26 mm while the 26s gauge needle has an O.D. of 0.47 mm and an I.D. of 0.13 mm. The 26s has half the I.D. of the 26 gauge needle. Also, the difference in the wall thickness nearly doubles with 26s gauge having a thickness of 0.18 mm while the 26 gauge is only 0.10 mm.

          Length

          No Information Available.

          Point Style

          Several different needle point styles are offered on Hamilton syringe and needle products depending on the application. The correct point style varies depending on the intended application. Below are a few examples of common applications.

          Animal Injections: Point Style 4 with a 45º angle allows for the most accurate targeting of a specific biological structure.

          Manual HPLC Injections: Most manual injection valves are designed to be used with a 22 gauge Point Style 3 needle.

          Manual GC Injections: Historically a Point Style 2 was required to achieve efficient septum penetration with minimized coring. With Hamilton’s new line of GC septa there is evidence that indicates the Point Style AS will consistently extend septa life by as much as 10-fold.

          Drawing Sample: Any point style will efficiently draw a sample, but when it is important to get the last drop out of a vial use Point Style 3 or AS to reach all the way to the bottom.

          Note: Syringes and needles manufactured by Hamilton Company are intended for scientific research and laboratory use only and are not intended for human in vivo use.


          Point Style 2
          Sharp, beveled, curved, non-coring needle point recommended for septum penetration.
          Available gauges: 33-10.






          Point Style 3
          Blunt needle point for use with HPLC injection valves and for sample pipetting.
          Available gauges: 33-10.






          Point Style 4
          Standard 12° beveled needle point is recommended for life science applications.
          Available gauges: 33-10. Special point styles such as 30°, 45°, or any other angle are available upon request.






          Point Style 5
          Conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.
          Available gauges: 26-10.






          Point Style AS
          Special conical style needle point used on autosampler syringes the non-coring needle point is recommended for septum penetration.
          Available gauges: 26 & 22.

          Glass Micro Pipettes

          This is an adapter that enables the connection of 1 mm Glass Micro Pipettes to any Hamilton Removable Needle syringe 100 μL and smaller.

          Stainless Steel Tubing

          This option is a needle without a hub for connecting to a syringe.  This option is often used for custom integrations where the cannula will be permanently welded or staked into another device.

          Valve Port - Hat Type Needles

          These needles are designed to seal into the valve port of a standard Hamilton syringe.

          VDRL Bent Needle

          This is a specialized, bent, 18 gauge, Kel-F hub needle for a repetitive antigen dispenser.

          Gel Loading Needles

          These are replacement needles for the fixed and adjustable width Gel Loading syringes.


          Website Feedback   |    Terms of Use   |    Privacy Policy   |    Partner Portal
          © 2013 Hamilton Company. All rights reserved. Hamilton Company, product and/or service names referenced are either trademarks or
          registered trademarks of Hamilton Company or its licensors in the U.S. and/or other countries. For details, visit www.hamiltoncompany.com/trademarks.

          For Sales and Product information, contact your local Hamilton Sales Office at (800) 648-5950.