Needles

Hamilton Company offers the widest variety of standard and custom needles in the industry. Manufactored from 304SS and with needle gauges from 10 to 33 and lengths from 0.375 to 6+ inches almost any needle is possible. Further narrow your search by selecting one of the categories to the right or select the “Part Number” button to see all Hamilton needles. A convenient filter tool is provided to narrow your search by Hub Style, Gauge, Length, or Point Style.

Luer Lock Needles


Hamilton Company offers a large selection of needles that are compatible with Luer Lock syringes. Luer Lock is an industry standard tapered termination utilized by most syringe manufacturers including medical Hypodermic syringes. Luer Lock needles are common because their design is controlled by a series of universal standards which guarantees compatibility between manufacturers. That being said not all luer lock needles are created equally.
Removable Needles (RN)


With Hamilton Removable Needles you get the best of both worlds. The benefit of a replaceable needle for the occasional bend or clog and the minimal dead volume of a cemented needle. The unique Removable Needle design installs the needle precisely at the zero line. The result is a zero dead volume connection that simplifies priming.
Specialty Needles


Over the years Hamilton Company has created a number of custom syringes and needles. This category contains all of the application specific needles for Neuroscience, OEM Integration, DNA Gel Loading, and more.
Roll the cursor over the menu headers below to see the available selections. Filter by one or more items in any order to narrow your search down to a single part number in this category. Reset a filter by clicking the red X that appears next to a filtered item. For more detail on any menu item, click the question mark on the right-hand side of the menu bar.

          Part Number
          Description
          Unit Price
          Quantity

          Hub

          Metal hub (nickel plated brass) needles can be used with TLL syringes and LT or TLL connectors. The needless are 304 stainless steel (sst.). Standard needle length is 2" / 51 mm. Metal hub (N) needles are available in convenient six packs. Custom needle lengths and point styles are available.

          Kel-F hub (KF) needles can be used with Luer Tip (LT) and PTFE Luer Lock (TLL) syringes and connectors. Standard needle length is 2" / 51 mm. Kel-F hub (KF) needles are available in convenient six packs. Custom lengths and point styles are available.

          Gauge

          When selecting a needle gauge it is important to keep in mind the volume of the syringe and the dead volume of the needle. For example, it will be very difficult to prime a 10 µL syringe if the dead volume in the needle is greater than 10 µL. Refer to the gauge index to choose a needle gauge with an appropriate µL/inch before selecting a needle. Select the minimum length that allows you to carry out your application comfortably.

          Note: The ‘s’ on a 22s needle represents a smaller I.D. (inner diameter) for the needle and a thicker needle wall for better durability. For example, a 26 gauge needle has an O.D. (outer diameter) of 0.46 mm and an I.D. of 0.26 mm while the 26s gauge needle has an O.D. of 0.47 mm and an I.D. of 0.13 mm. The 26s has half the I.D. of the 26 gauge needle. Also, the difference in the wall thickness nearly doubles with 26s gauge having a thickness of 0.18 mm while the 26 gauge is only 0.10 mm.

          Length

          No Information Available.

          Point Style

          Several different needle point styles are offered on Hamilton syringe and needle products depending on the application. The correct point style varies depending on the intended application. Below are a few examples of common applications.

          Animal Injections: Point Style 4 with a 45º angle allows for the most accurate targeting of a specific biological structure.

          Manual HPLC Injections: Most manual injection valves are designed to be used with a 22 gauge Point Style 3 needle.

          Manual GC Injections: Historically a Point Style 2 was required to achieve efficient septum penetration with minimized coring. With Hamilton’s new line of GC septa there is evidence that indicates the Point Style AS will consistently extend septa life by as much as 10-fold.

          Drawing Sample: Any point style will efficiently draw a sample, but when it is important to get the last drop out of a vial use Point Style 3 or AS to reach all the way to the bottom.

          Note: Syringes and needles manufactured by Hamilton Company are intended for scientific research and laboratory use only and are not intended for human in vivo use.


          Point Style 2
          Sharp, beveled, curved, non-coring needle point recommended for septum penetration.
          Available gauges: 33-10.






          Point Style 3
          Blunt needle point for use with HPLC injection valves and for sample pipetting.
          Available gauges: 33-10.






          Point Style 4
          Standard 12° beveled needle point is recommended for life science applications.
          Available gauges: 33-10. Special point styles such as 30°, 45°, or any other angle are available upon request.






          Point Style 5
          Conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.
          Available gauges: 26-10.






          Point Style AS
          Special conical style needle point used on autosampler syringes the non-coring needle point is recommended for septum penetration.
          Available gauges: 26 & 22.



          Website Feedback   |    Terms of Use   |    Privacy Policy   |    Partner Portal
          © 2013 Hamilton Company. All rights reserved. Hamilton Company, product and/or service names referenced are either trademarks or
          registered trademarks of Hamilton Company or its licensors in the U.S. and/or other countries. For details, visit www.hamiltoncompany.com/trademarks.

          For Sales and Product information, contact your local Hamilton Sales Office at (800) 648-5950.