U S A 
Contact Hamilton

Replacement parts for SofTouchT pipettes are readily available to maximize pipette life and keep your pipette performing optimally. An overview of available parts is shown here; for a complete list, please contact Hamilton. Service and calibration are also available through Hamilton's Complete Pipette Service
 


Single Channel Pipettes



Pipette Volume, µL

0.2-10 µL 5-100 µL 50-1000 µL 100-5000 µL
1. Tip ejector assembly 9148-01 9148-01 9148-01 9148-01
2. Tip ejector collar 9155-01 9156-01 9157-01 9158-01
3. On-off assembly 9169-01 9169-01 9169-01 9169-01
4. Bottom plate assembly* 9170-01 9170-01 9170-01 9170-01
5. Battery Cover 9171-01 9171-01 9171-01 9171-01
6. Cover assembly 9172-01 9173-01 9174-01 9175-01
7. Finger grip 9178-01 9178-01 9178-01 9178-01
8. Keyboard 9179-01 9179-01 9179-01 9179-01
Piston assembly 9151-01 9152-01 9153-01 9154-01
Battery, NiMH 9168-01 9168-01 9168-01 9168-01
Silicon grease, 15 mL 9207-01 9207-01 9207-01 9208-01



Multi-Channel Pipettes



Pipette Volume, µL

0.2-10 µL 5-100 µL 25-250 µL 50-1200 µL
1. Tip ejector assembly 9181-01 9181-01 9181-01 9181-01
2. Tip ejector collar N/A N/A N/A N/A
3. On-off assembly 9169-01 9169-01 9169-01 9169-01
4. Bottom plate assembly* 9170-01 9170-01 9170-01 9170-01
5. Battery Cover 9171-01 9171-01 9171-01 9171-01
6. Cover assembly 9172-01 9173-01 9176-01 9177-01
7. Finger grip 9178-01 9178-01 9178-01 9178-01
8. Keyboard 9179-01 9179-01 9179-01 9179-01
9. Tip cone housing, 8 ch 9186-01 9188-01 9188-01 9190-01
10. Tip cone housing, 12 ch 9187-01 9189-01 9189-01 9191-01
Piston assembly 9198-01 9199-01 9200-01 9201-01
Battery, NiMH 9168-01 9168-01 9168-01 9168-01
Silicon grease, 15 mL 9207-01 9207-01 9207-01 9207-01
*includes battery cover


Pipette Safe™ Tip Cone Filters

The tip cones of select SofTouch electronic pipettes allow the use of a removable Pipette Safe tip cone filter. This innovative safety feature prevents cross contamination of sample fluids or vapors, particularly when pipetting radioactive or biohazardous samples. Pipette Safe Plus tip cone filters seal when wetted for even greater protection.

In order to properly protect the internal mechanism of the pipette, filters need to be changed regularly depending on the application. A general guideline is to change the filter daily (50-250 pipettings) and always in case of over-aspiration. The filter does not affect the calibration of the pipette.




Pipette Volume
Range
Pipette Safe
Filter
Pipette Safe
Plus Filter
50-1000 µL, single channel 9209-01 9211-01
100-5000 µL, single channel 9209-01 9211-01
5-100 µL, multi-channel 9210-01 N/A
25-250 µL, multi-channel 9210-01 N/A
50-1200 µL, multi-channel 9209-01 9211-01



About Hamilton Contact Quick Order Service News & Promos

Copyright 1998-2008 Hamilton Company. All Rights Reserved.
Terms of Use. Privacy Statement.